|
| TM 11-5820-695-35
Item No.
Symptom
Probable trouble
Corrective action
31 Meter indication for 3RD
MULT (LOCAL OSC)
MULT. If meter indication is
meter selector switch posi-
not in yellow band, perform the
tion not in yellow band.
corrective action given for item
No. 30 in this chart. If meter
indication is in yellow band,
calibrate the 3RD MULT
(LOCAL OSC) metering cir-
cuit (para 3-59).
b. Coaxial circulator 1A10HY1
b. Replace coaxial circulator
defective.
1A10HY1 (para 3-27)
32 Meter indication for RF
a. Meter calibration required----------------a. Calibrate the T-1054(P)/GRC-144(V)
POWER meter selector
rf power metering circuit
switch position not in yellow
band.
b. Same as item No. 19 in this chart-----b. Perform the corrective action
given In item No. 19 in this
chart.
33 Meter indication for REFL
RF POWER meter selector
reflected rf power metering
switch position is greater
circuit (para 3-58).
than 20.
b. Defective wiring in plate assembly
b. Perform the corrective action
1A16.
given for item No. 21 in this
chart.
34 Meter indication for OW
a. Defective wiring In plate assembly
a. Perform the plate assembly 1A16
TEST meter selector switch
1A16.
checks (para 3-10c, section 2).
position not 100 10.
b. Defective wiring in electrical
b. Perform the electrical equipment
equipment cabinet 1A15.
cabinet 1A15 checks (para
c. Digital data modem chassis
c. If standard cable terminal opera-
1A12A12 defective.
tion is being used, replace digital
data modem chassis 1A12A12
35 Modulator frequency not 50
a. Modulator frequency adjustment
MHz +20 kHz as deter-
required.
adjustment (para 3-62).
mined by test (para 3-71).
b. Component 1A8 or 1A7
b. Check components 1A8 and 1A7
defective
by substitution (TM 1-5820-
695-12).
36 Electrical frequency synthe-
a. Defective component in electrical
a. One at a time, replace each com-
sizer 1A14 frequency error
frequency synthesizer 1A14.
ponent (1A14A1 through
greater than 3 kHz as
1A14A7) in electrical frequency
determined by test (para
synthesizer 1A14 (TM 11-
3-71).
5820-695-12).
b. Electrical equipment chassis
b. Replace electrical equipment
1A14A10 defective.
chassis 1A14A10 (para 3-31).
CHANGE 6
3-8.1/(3-8.2 blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |