TM 11-5820-695-35
h.
Remove Dummy Load, Electrical DA-641/
h.
Remove Dummy Load, Electrical DA-
41/ GRC from Adapter, Waveguide UG-1883/GRC and
GRC from Adapter, Waveguide UG-1883/GRC and
connect the test equipment in figure 3-29.
connect the test equipment as shown in figure 3-29.
i.
Adjust the PUSH TO TURN control on
i.
Adjust the PUSH TO TURN control on radio
frequency bandpass filter 1FL3 until a null is obtained on
radio frequency bandpass filter 1FL3 until a null is
AN/USM-161 NULL INDICATOR meter.
obtained on AN/USM-161 NULL INDICATOR meter.
j.
Set Switch, Waveguide SA-1679/GRC to
j.
Turn  the  meter  selector  switch
the TO ANT. (NORMAL) position.
1A15A8S4 on meter panel assembly 1A15A8 to RF
POWER.
k.
Turn the AN/USM-161 off and disconnect
k.
Remove the protective plate over the
cable assembly CG-2514/U from Adapter, Waveguide
UG-1883/GRC.
potentiometer  bracket  and  adjust  potentiometer
1A15A8R6, figure 34. If a meter indication-of 60 cannot
l.
Connect the 3 db attenuator and type N
be obtained, refer to the troubleshooting chart (item No.
short (fig. 3-29) to Adapter, Waveguide UG-1883/GRC.
69, para 386b) for corrective action upon completion of
m.
Set Switch, Waveguide SA-1679/GRC to
this procedure.
the TO LOAD (TEST) position.
l.
Reset the controls on radio frequency
n.
Turn meter selector switch 1A15A8S4 on
bandpass  filter  1FL3  and  electrical  frequency
meter panel assembly 1A15A8 to REFL RF POWER.
synthesizer 1A14 to the original operating frequency
recorded in step f.
o.
Remove the protective plate over the
potentiometer  bracket  and  adjust  potentiometer
m.
Set
Switch,
Waveguide
SA-
1A15A8R5 (fig. 3-4) for a 1A15A8M1 meter indication
1679/GRC to the TO ANT. (NORM-AL) position.
of 20. If a meter indication of 20 cannot be obtained,
n.
Connect Dummy Load, Electrical DA-
refer to the troubleshooting chart (item No. 40, para 3-
541/ GRC to Adapter, Waveguide UG-1883/GRC.
6b) for corrective action upon completion of this
procedure.
o.
Turn  off  the
AN/USM-161
and
disconnect the test equipment.
p.
Set the controls on electrical frequency
synthesizer 1A14 and radio frequency bandpass filter
3-58. Calibration
of
T-1054(P)A/GRC-144(V)
1FL3 to the original operating frequency recorded in
Reflected RF Power Metering Circuit
step f.
a.
Turn on Test Set, Radio Frequency Power
q.
Set Switch, Waveguide SA-1679/GRC to
AN/USM-161 and allow a 30-minute warmup period.
the TO ANT. (NORMAL) position.
b.
Calculate the calibration plate correction
r.
Disconnect the 3 db attenuator and type N
factors of the two CN-845/USM-161's and the CG-
short from Adapter, Waveguide UG-1883/GRC.
2514/U (fig. 3-29) for a 4800 MHz input. Algebraically
add the correction factors noting the plus or minus sign
s.
Connect Dummy Load, Electrical DA-541/
and record.
GRC to Adapter, Waveguide UG-1883/GRC.
c.
Calibrate  the  AN-/USM-161
using
the
3-59. Calibration of T-1054(P)/GRC-144(V) and T-
procedures given in TM 11-6625-498-12.
1054(P)A/GRC-144CV) Frequency Multiplier Metering
d.
On the AN/USM-161, set the BIAS-READ
Circuits.
switch to READ, turn the POWER RANGE switch to 3.0
NOTE
MW +6 DPM, set the COMP ATTENUATOR dial to the
Do not calibrate any of the T-1054(P)/
value recorded in step b above, and set the POWER
GRC-144(V)
frequency
multiplier
indicator dial for a dial scale indication of 1.6 on the
metering  circuits  when  the  T-
center scale.
1054(P)/GRC-144(V) output power is
e.
Set Switch, Waveguide SA-16789/GRC to
less than 150 milliwatts. If the output
the TO LOAD (TEST) position.
power level is not known, use the T-
f.
Record  the  T-1054/GRC-144  operating
1054(P)/GRC-144(V)  output  power
frequency and then set the controls on electrical
test (para 3-72) to determine it.
frequency synthesizer 1A14 to 4800.0 MHz.
To calibrate any of the T-1054/GRC-144 frequency
g.
If the RF POWER indicator on meter panel
multiplier metering circuits, turn meter selector switch
assembly 1A15A8 is not lighted red, adjust the PUSH
1A15A8S4 (fig. 3-4) to the circuit to be calibrated and
TO TURN knob on radio frequency bandpass filter 1FL3
observe the indication on meter 1A15A8M1. If meter
until it lights red.
indication is not 100, remove the protective plate over
the potentiometer
Change 6
3-77