| TM 11-5820-695-35
connector 1A16W25XA2 (fig. 3-2 and 5-15(1)).
e.
Turn Test Set, Electrical Meter TS-656/U on
i.
Connect a test lead between the COMMON
and allow a 5-minute warmup period.
terminal on T-6/U and pin 9 of 100 MHz oscillator
f.
On the TS-656/U, set the FUNCTION switch
connector 1A16W25XA2.
to DIR CUR, the CURRENT switch to 100 MICRO-AMP,
j.
On TS-656/U, hold the TEST switch in
and turn the DECREASE/ INCREASE control
TEST (up) position and turn the DECREASE/
counterclockwise until mechanical stop is reached.
INCREASE control in INCREASE direction (clockwise)
g.
Connect the red test lead supplied with
until indication on meter 1A16M2 reaches SET OSC
TS656/U between the DIR CUR terminal on TS656/U
LEVEL ADJ.
and the TEST LEAD jack on meter panel assembly
k.
With the TEST switch on TS-656/U in the
1A15A8.
up position, the meter on TS-656/U should indicate 40
h.
Connect the black test lead supplied with
+2.0 microamperes. If it does not, replace meter
TS-656/U between the COMMON terminal on TS-656/U
1A16M2 (para 3-35) and repeat the calibration
and the El CABINET GROUND lug on top of electrical
procedure.
equipment cabinet 1A15 (fig. 3-7).
I.
Turn the TS-656/U off and disconnect the
i.
On TS-656/U, hold the TEST switch in
test leads.
TEST (up) position and turn the DECREASE/
m.
Reinstall component 1A2 and connect
INCREASE control in INCREASE direction (clockwise)
cables 1A2W1 and 1A2W2.
until meter 1A15A8M1 indicates 150.
n.
Turn meter switch 1A16S5 on the radio test
j.
With the TEST switch on TS-656/U in the
set meter panel to OFF (TRANSIT).
up position, the meter on TS-656/U should indicate 37.5
1.5 microamperes. If it does not, replace meter
o.
Set the POWER ON/OFF switch 1A15A8S3
1A15A8M1 (para 321a) and repeat the calibration
on meter panel assembly 1A15A8 to ON.
procedure.
3-57. Calibration of T-1054(P)/GRC-l44(V) Reflected
k.
Turn the TS-656/U off and disconnect the
RF Power Metering Circuit
test leads.
a.
Turn on Test Set, Radio Frequency Power
l.
Set POWER ON/OFF switch 1A15A8S3 on
AN/USM-161 and allow a 30-minute warmup period.
meter panel assembly 1A15A8 to ON.
b.
Calculate the calibration plate correction
3-56. Calibration of Transmitter Meter 1A16M2
factors of the CN-845/USM-161 and CG-2514/U (fig. 3-
a.
Set POWER ON/OFF switch 1A15A8S3 on
29) for a 4800 MHz input. Algebraically add the
meter panel assembly 1A15A8 (fig. 3-1) to OFF.
correction factors noting the plus or minus sign.
b.
Turn meter switch 1A16S5 on the radio test
c.
Calibrate the AN/: USM-16,1 using the
set meter panel to OFF (TRANSIT).
procedure given in TM 11 49812.
c.
Using a screwdriver, adjust the screw on
d.
On the AN/USM-161, set BIAS-READ
front of meter 1A16M2 (fig. 3-12) for a zero meter
switch to REAM, turn the POWER RANGE switch to 10
indication (a zero meter indication is obtained when the
MW +10 DBM, set the COMP ATTENUATOR dial to
meter pointer rests on the thin black line located to the
the value recorded in step b above, and set the POWER
left of the yellow meter band).
indicator dial for a dial scale indication of .75 on the
outermost scale.
d.
Disconnect cables 1A2W1 and 1A2W2 and
remove 100 MHz oscillator 1A2.
e.
Set Switch, Waveguide SA-1679/GRC to
the TO LOAD (TEST) position.
e.
Set radio test set switch 1A16S5 to the OSC
LEVEL position.
f.
Record
the
T-1054(P)/GRC-144(V)
operating frequency and then set the controls on
f.
Turn Test Set, Electrical Meter TS-66/U on
electrical frequency synthesizer 1A14 to 4800.0 MHz.
and allow a 5-minute warmup period.
g.
If the RF POWER indicator on meter panel
g.
On the TS--656/U, set the FUNCTION
assembly 1A14A8 is not lighted red, adjust the PUSH
switch to DIR CUR, the CURRENT switch to 100
TO TURN knob on radio frequency bandpass filter 1FL3
MICRO-AMP, and turn the DECREASE/ INCREASE
until it lights red.
control counterclockwise until mechanical stop is
reached.
h.
Connect a test lead between the DIR CUR
terminal on TS-656/U and pin 5 of 100 MHz oscillator
Change 6
3-76
|