| TM 11-5820-695-35
assembly 1A16. Tighten the two captive screws on
(5) Tag and unsolder wires connected to
each component.
terminals of power transformer 1A16A1OT1.
(6) Exercising care not to put stress on cable
harness wiring, remove power transformer lAl5AlOT1
(9) Remove the masking tape securing
from electrical equipment cabinet 1A15.
coaxial cables 1A15W27W9 and 1A15W16 to the sides
of electrical equipment cabinet LA15.
(10) Reconnect coaxial cables 1A2W1,
b. Replacement.
1A2W2, 1A3W1, 1A15W27W9, and 1A15W16 to the
components (fig. 8-13).
CAUTION
Exercise care while soldering the
CAUTION
cable harness leads to the power
Replacement of rigid coaxial cables
transformer terminals to prevent
must, be performed carefully to
damage to the cable harness leads or
prevent damage to the rigid coaxial
power transformer terminals.
cables.
(1) Solder wires removed in step a(5) above
(11) Connect rigid coaxial cable 1W17
to correct terminals of replacement power transformer
between 1HYlJl and 1AllJ5 (TM 114820-69612).
lA15A1OT1.
(12) Replace power supply 1A1 (para 8-22g (6)
(2) Insert the four mounting screws and
through (10)).
washers, removed in step a(4) above, into the power
(13 Restore power to T-1054(P)/GRC-144(V) or T-
transformer base mounting holes and then carefully
1054(P)A/GRC-144(V) (para 3-20b).
lower LA15A1OT1 onto the mounting bracket while
aligning the visible mounting screws with the bracket
mounting holes.
3-33. Replacement of Parts on or behind Plate
Assembly 1A1 6 (fir. 8and 3-16)
(3) Replace the four nuts on power
transformer lA15AlOTl mounting screws and secure
Plate assembly 1A16 must be removed from electrical
lA15AlOTl to the mounting bracket by tightening the four
equipment cabinet 1A15 (para 3-82) to gain access to
nuts firmly.
any of the parts mounted on the rear of plate assembly
(4) Position and fasten the three cable
1A16 (fig. 315) or to any of the parts mounted on
clamps on cable harness lA15AlOWl with the three
electrical equipment cabinet lA1S behinds plate
cable clamp nuts removed in step a(8).
assembly IA16 (fig. 3-8). Procedures are ,provided for
(5) Replace plate assembly 1A16 (para
replacement of power transformer 1A15A1OTl (para 8-
882b).
4), parts in the radio test set (para -85), and radio
(6) Restore power to T-1054(P)/GRC-144 (V)
frequency bandpass filter 1PO, radio frequency low pass
or T-1054(P)A/GRC-144(V) (para 3-20b).
filter 'IFIA, elbow adapter 1OP4, or directional coupler
LDC1 (para 386). All other parts can be replaced using
3-35. Replacement of Parts In Radio Test Set (p/o
general replacement techniques (par 3-19).
1A16) (fig. 8-12)
3-34.
Replacement
of
Po4ir
Transformer
a. Removal.
1A1SA1OT1 (fig.-8)
(1) Set the POWER ON/OFF switch on
a. Removal.
meter panel assembly 1A15A8 to OFF.
(I) Remove
power
from
T-
(2) Loosen the two set screws securing each
1054(P)/GRC144(V) or T-1054(P)A/GRC-144(V) (para
selector knob on the radio test set meter panel and
remove the selector knobs.
(2) Remove plate assembly 1A16 (pars
(3) Remove the two screws securing crystal
832a).
mixer 1A16Z1 mounting bracket to the radio test set
(3) Remove the three cable clamp nuts
meter panel.
securing cable harness lA15AlOWl (fig. 8-) to cabinet
(4) Remove the three screws securing
wall. Do not remove the cable clamps from the cable
variable attenuator 1A16AT1 to rear of the radio test set
harness.
meter panel.
(4) Loosen and remove the four screws, four
(5) Remove the eight screws securing the
washers and four nuts securing the base of power
radio test set meter panel to the radio test set enclosure.
transformer 1A15A1OT1 to mounting bracket.
Change 6
3-53
|