(6) Pull the radio test set meter panel away
(10) Solder switch wires to rotary switch
from the radio test set enclosure until it is clear of the
1A16S5 terminals.
shaft on variable attenuator 1AI6AT1, then lower the
(11) Using a -pair of needle nose pliers to hold
meter panel assembly.
crystal mixer lA16Z1 mounting bracket, place the radio
(7) Remove the two self-locking nuts and
test set meter panel on the radio test set enclosure.
washers from the meter terminals.
(12) Replace and tighten the two screws
(8) Tag and remove the wire lugs connected
securing crystal mixer 1A16Z1 mounting bracket.
to the meter terminals.
(13) Replace and tighten the three screws
(9) Remove and save the three locknuts,
securing variable Attenuator 1A16AT,1.
washers, and screws securing meter 1AI16M2 to the
(14) Replace and tighten the eight screws
radio test set meter panel, then lift and remove meter
securing the radio test set meter panel to the radio test
1A16M2.
set enclosure.
(10) Tag and unsolder all wires connected to
(15) Replace the selector knobs on variable
rotary switch 1A16S5.
attenuator 1A16AT1 and rotary switch 1A16S5 and
(11) Remove hex-nut and washer that secures
tighten the two set screws on each knob.
switch 1A16S5 and remove the switch.
(16) Connect cable 1A15W26 to 1A16AT1J2.
(12) 'Disconnect coaxial cable 1A16W24 from
(17)  Perform  the  T-1054(P)/GRC-144(V)  and  T-
crystal mixer 1A16ZIJ2 and cable 1A15W26 from
1054(P)A/GRC-144(V)  radio  test  set  calibration
1A16AT1J2.
procedure (para 341).
(13) Pull variable attenuator 1A16AT1 and
3-36.
Replacement of Radio Frequency Sandpass
crystal mixer 1A16Z1 forward out of radio test set
Filter 1FL3, Radio Frequency Low Pass Filter
enclosure as a unit.
1FL4, Elbow Adapter 1CP4, or Directional
(14) Disconnect mating type N connectors as
Coupler 1DC1 (fig. 3-2, 3-13 and 3-15)
required, to separate variable attenuator A1l6AT1 and
crystal mixer 1A16Z1 from each other.
Removal and replacement procedures for any of the
following; radio frequency bandpass filter 1FL3, radio
b. Replacement.
frequency low pass filter 1F4IA, elbow adapter 1CP4 or
directional  coupler  1DC1  require  assembly  and
(1) Assemble variable attenuator 1A16AT1 and
disassembly of the remaining components.
The
crystal mixer 1A,11i6Zl together by reconnecting the
following procedures detail the steps necessary to
mating type N connectors and mount them in the radio
remove all three components as a single item which can
test set enclosure by pushing the type N connector on
be further disassembled when removed from T-
rear of variable attenuator 1A1AT1 through the rubber
1054(P)/GRC-144(V) or T-1054(P)A/GRC-I 44(V).
grommet at the back of the radio test set enclosure.
(2) Rotate knob shafts on variable attenuator
(1) Remove power from T-1054(P)/GRC-144
1A16AT1  and  rotary  switch  1A16S5  completely
6() or T-1054(P)A/GRC.-144(V) (para 3-20ag.
clockwise.
(2) Remove plate assembly 1A16 (para
(3) Connect coaxial cable 1A16W24 to crystal
332a).
mixer 1A16Z1 (4) Mount meter 1A16M2 to the radio test
(3) Disconnect the following coaxial cables
set meter panel.
from components mounted on plate assembly lA16:
(5) Replace and tighten the three screws and
1A9W9 from radio frequency bandpass filter 1FL3
locknuts (and lockwashers) securing meter 1A16M2 (6)
connector J1, 1A16W24 from directional coupler 1DC1
Remove the two self-locking nuts and washers from the
connector RF INCIDENT Jo, 1A16W22 from directional
meter terminals, then remove the shorting bar from
coupler 1DO1l connector INGIDE'NT J4, and 1A16W26
across the meter terminals.
from directional coupler 1DCl connector REFLECTED
(7) Connect the wire lugs to meter terminals and
J6.
secure them with the two self-locking nuts and washers.
(4) Remove the four screws and washers
(8) Mount rotary switch 1A16S5 on meter panel
securing radio frequency bandpass filter 1FL3 to plate
assembly removed in a(11) above.
assembly 1A16.
(9) Replace and tighten the hex nut and washer
('5) Disconnect radio frequency bandpass filter 1FL3
securing rotary switch 1A16S5.
from radio frequency low pass filter 1FL4 by rotating the
knurled connector on 1FIA in a clockwise direction.
Remove 1FL3 from plate assembly 1A16.
Change 6