| TM 11-5820-695-35
in plate assembly 1A16. If the mounting holes on 1FL3
NOTE
cannot be aligned with the mounting holes in 1A16,
If radio frequency bandpass filter
loosen the four iDC1 mounting bracket screws (fig. 3-2)
1FL3 is the only component to be
and then align the mounting holes.
replaced; proceed to step b(6) below.
(7) Insert and tighten the four screws and
washers that secure radio frequency bandpass filter
(6) Disconnect radio frequency low pass filter
1FL3 to plate assembly 1A16.
1FIA from elbow adapter 1CP4 by rotating the knurled
(8) Tighten the four 1DC1 mounting bracket
connector on 1FIA in a counterclockwise direction.
screws if they were loosened in step (6) above.
Remove 1FIA by pulling it through the connector access
hole in plate assembly 1A16.
(9) Tighten the four screws that secure 1DC1
to the lDC1 mounting bracket.
NOTE
(10) Reconnect coaxial cables 1A9W9 to radio
If radio frequency low pass filter
frequency bandpass filter 1FIA, 1A16W24 to directional
1FL4 is the only component to be
coupler IDC1 connector RF INCIDENT J3, 1A16W22 to
replaced; proceed to step b(8) below.
directional coupler LDC1 connector INCIDENT J4, and
lAlEW2B to directional coupler 1IDCl'connector
REFLECTED J5.
(7) Disconnect elbow adapter 1CP4 from
NOTE
directional coupler 1DC1 by rotating the knurled
If the four 1DC1 mounting bracket
connector on 1CP4 in a counterclockwise direction.
screws were loosened in step ((6)
Remove elbow adapter 1CP4.
above; it may 'be necessary to
reposition the plate assembly guide
NOTE
bracket (fig. 68) to permit installation
If elbow adapter 1CP4 is the only
of plate assembly lA16. If the plate
component to -be replaced; proceed
assembly guide bracket must be
to step b(2) below.
repositioned, loosen the four screws
that secure the guide bracket until
(8) Remove the four screws and washers
the plate assembly guide bracket can
securing directional coupler IDC1 to 1DC1 mounting
be moved up or down but still
bracket.
maintains its position when released,
then insert plate assembly 1AIC into
b. Replacement.
position in electrical equipment
cabinet 1A16.
Remove plate
(1) Mount directional coupler 1DC1 to
assembly lAl1 and tighten the four
1DC1 mounting bracket and loosely secure 1DC1 in
screws that secure the plate
place using the four screws and washers removed in
assembly guide bracket being sure
step a(8). Do not tighten the four screws at this time.
that the guide bracket does not move
(2) Mate the knurled connector on elbow
up or down.
adapter 1OP4 with the connector on the bottom of
directional coupler 1DC1 and rotate the knurled
(11) Replace
plate
assembly
1A16
(para
connector clockwise two complete turns.
832b).
(3) Mate the connector on radio frequency
bandpass filter 1FL3 with the knurled connector on radio
(12) Perform the T-1054(P)/GRV-144V) and T-
frequency low pass filter 1FL4A. Tighten the knurled
1054(P)A/GRC-144(V) rf power metering circuit
connector.
calibration procedure (para 3-57) 3-37. Repair and
(4) Insert radio frequency low pass filter 1FL4
Replacement of T-1054(P)/ GRC-144(V) and T-
through the connector access hole in plate assembly
1054(P)A/GRC144(V) Connectors (fig. 3-14, 3-26)
1At16.
(5) Mate the knurled connector on radio
a. General.
Repair of connectors in T-
frequency low pass filter 1FAL4 with the connector on
1054(P)/GRC-144(V)
and
T-1054(P)A/GRC144()
elbow adapter 1CP4. Tighten the knurled connectors on
requires either: the replacement of the deffective
1FIL4A and 1CP4.
connector (solder type nonremoveable contacts), or the
replacement of defective connector contacts (crimp or
(6) Align the mounting holes on radio
solder type removable contacts).
A listing of
frequency bandpass filter 1FL3 with the mounting holes
Change 6
3-55
|