| TM 11-5820-695-35
Figure 3-14. Repair detail, rectangular connectors with solder type removable coaxial contacts
(11) Set the POWER ON/OFF switch on meter panel
(3) Remove connector 1A15P3 (fig.
8-7) from
assembly 1A15A8 to ON.
STORAGE
J21 or FAULT LOCATOR POWER
SUPPLY INTERCONNECT 20 at top of electrical
3-23. Replacement of Vane Axial Fan 1A1581 (fig. 3-
equipment cabinet 1A15 to provide access to air
3 and 3-4)
exhaust filter 1A15MP2.
a. Removal.
(4) Loosen the four thumbscrews securing
(1) Remove power from T-1054/GRC-144
air exhaust filter 1A15MP2 to top of electrical equipment
(para 5-20a).
cabinet 1A15 and remove the filter.
(2) Remove power supply 1A1 (para 8-22&
(5) While supporting the fan 1A15B1 inside
(2) through (6)).
of the cabinet, loosen, but do not remove
3-44
|