|
| TM 11-5820-695-35
Figure 3-13. Transmitter, Radio T-1054/GRC-144, cable locations
(3) Repeat steps (1) and (2) for regulators
(7) Tilt the power supply to a level position
1A1A2, 1A1A3, and 1A1A4.
when approximately 3 inches of the front part of power
supply remains out of the inclosure, then push power
(4) Mount blank panel A1A5 on power
supply into the cabinet until guide pins and connectors
supply chassis assembly 1A1A13 and secure in place
are mated.
using the original mounting hardware.
(8) Alternately tighten the two power supply
(5) Repeat steps (1) and (2) for regulators
captive screws two turns at a time until the power supply
1A1A6 through 1A1A12.
is securely fastened to the cabinet.
(6) Position power supply 1A1 into its
(9) Release the meter panel assembly
inclosure in electrical equipment cabinet 1A15 with the
1A15A8 and position it downward until it rests against
front end of power supply tilted downward. Slowly slide
the cabinet.
power supply into the cabinet taking care not to damage
meter panel cables.
(10) Secure meter panel assembly 1A15A8
by tightening the two meter panel captive screws.
3-43
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |