TM 11-5820-695-35
Item No.
Symptom
Probable trouble
Corrective action
24 RADIO REPEATER OPERA-
a. Defective wiring in electrical
a. Use the T-10 U4/OFR-144 inter-
TION indicator not lighted
equipment cabinet 1A15.
connecting diagram (fig. 5-16)
and standard radio repeater
and TS-352 B/U to check con-
operation is being used.
tinuity of wiring between pin 2
of connector 1A15W27XA1B and
indicator assembly 1A1XDS28.
b. Indicator assembly 1A15XDSZ
b. Replace indicator anembly
defective.
1A16XDS2s (fig. 5-15).
25
CABLE TERMINAL OP-
a. Defective wiring in electrical
a. Use the T-1014/GR-144 inter-
ERATION indicator not
equipment cabinet 1A15.
connecting diagram (fig. 615)
lighted and standard cable
and TS452 B/U to check con-
terminal operation is being
tinuity of wiring between pin
used.
2 of connector 1A15WT7XA1B
and indicator assembly
1A15XDSZ2.
b. Indicator assembly 1A16XDS22
b. Replace indicator assembly
defective.
1A16XDS22 (fig. 3-5).
26 Meter indication for MODU-
Defective wiring or component in
Perform the plate assembly 1A16
LATOR OUTPUT, FREQ
plate assembly 1A16.
checks (para 3-10c, sections 5
CONTROL CTR FREQ,
and 6).
or FREQ CONTROL OUT-
PUT meter selector switch
position not in its color
band.
27 Meter indication for TRAF-
a. Meter calibration required ------------------a. Calibrate the T-1054/GRC-144
FIC meter selector switch
traffic metering circuit (para
position not in orange band.
3-60).
b. Defective wiring in plate assembly
b. Perform the corrective action
1A16.
given for-item No. 18 in this
chart.
28 Meter indication for SYN-
a. Defective wiring in electrical
a. Perform the electrical equipment
THESIZER meter selector
equipment cabinet LAI1.
Cabinet1A1S checks (para
switch position not in yellow
3-11c, section 8).
band.
b. Electrical equipment chassis
b. Replace electrical equipment
1A14A10 defective.
chassis 1A14A10 (para 3-1).
29 Meter indication for AMPI,
a. Meter calibration required-------------------- a. Turn meter selector switch to
MULT meter selector
SYNTHESIZER If meter in-
switch position in yellow
dication is not in yellow band,
band.
perform the corrective action
given for item No. 28 in this
chart If meter indication is In
yellow band, calibrate the
AMPILMULT metering cir-
cuit (pare 3849).
b. Defective wiring in plate assembly
b. Perform the plate assembly 1A16
1A16.
checks (para 3-10c, section 7).
c. Coaxial cable lA16W16 defective-----------c. Check coaxial cable 1A1SW16
(fig. 3-13) by substitution.
d. Coaxial circulator 1HY1 defective---------- d. Replace coaxial circulator 1HY1
30 Meter indication for 2ND
a. Meter calibration required-------------------- a. Turn meter selector switch to
MULT meter selector switch
AMPI-PLMULT. If meter indi-
position not in yellow band.
cation is not in yellow band,
perform the corrective action
given for item No. 29 in this
chart. If meter indication is in
the yellow band, calibrate the
2ND MULT metering circuit
b. Coaxial circulator 1HY1 defective----------- b. Replace coaxial circulator 1HY1
CHANGE 6 3-8