| TM 11-5820-695-35
NOTE
For Radio Sets AN/GRC-144(V)3 and AN/GRC-144()4 check Switch, Waveguide SC-D-958093-001
(AN/TRC-175) K band, SC-D-958093-002 (AN/TRC-138) SRWBR receiver, or SC-D-958093-003
(AN/TRC-138) SRWBR transmitter.
37
T-1054(P)/GRC-144(V) rf output
a.
Same as item No. 19 in this chart
a.
Perform the corrective action for
power less than 150 milli-
item No. 19 in this chart.
watts as determined by test
b.
Switch, Waveguide SA-1679/GRC
b. Check Switch, Waveguide SA-
defective.
1679/GRC by substitution.
c. Adapter, Waveguide UG-1883/
c. Check Adapter, Waveguide UG-
GRC defective.
1883/GRC by substitution.
38
Cannot calibrate the T-
Defective component or wire in
Remove alarm monitor 1A5 (TM 11-
1054(P)/GRC-144(V) traffic
metering circuit.
5820-695-12) and check resis-
metering circuit (para 3-60).
tance between pin 12 of
connector 1A16W25XA6B and
the E1 CABINET GROUND lug
on top of 1A15 (fig. 5-15). Note
that resistance varies smoothly
from zero to 5,000 ohms as
potentiometer 1A15A8R7 (fig. 3-
4) is varied from one extreme to
the other.
Make the same
resistance check between pin 17
of 1A15A8S4B and pin 12 of
connector 1A16W25XASB.
Change 6 3-9
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |