| TM 11-5820-695-35
(3) Connect
plug
2A16W1P1
to
(3) Slide
replacement
electrical
connector 2A15W2J1.
frequency synthesizer 2A14 into the cabinet, aligning
the mounting guide pins with the mounting holes in the
(4) Connect the following coaxial cables:
cabinet. Carefully push electrical frequency synthesizer
2A15W1 to postselector bandpass filter 2FL6 connector
2A14 into the cabinet until connectors are mated.
J1, 2A15W3 to electrical frequency synthesizer 2A14
connector output J8 and amplifier frequency multiplier
(4) Alternately tighten the two 2A14
2A10 connector J2, and 2A15W10 to af-rf amplifier
captive screws securing the synthesizer to the cabinet.
2A11 connector J2.
(5) Reconnect coaxial cable 2A15W3 to
(5) Restore
power
to
R-
electrical frequency synthesizer 2A14 front panel
1467(P)/GRC144(V) or R-1467(P)A/GRC-144(V) (para
connector OUTPUT J8.
(6) Set the POWER ON/OFF switch on
3-51. Replacement of Parts on or behind Plate
meter panel assembly 2A15A2 to ON.
Assembly 2A16 (fig. 3-21)
3-50. Removal of Plate Assembly 2A16(fig. 3-17)
Plate Assembly 2A16 must be removed from electrical
a.
Removal/.
equipment cabinet 2A15 (para 3-50 ) to gain access to
(1) Remove
power
from
R-
any of' the parts mounted on the rear of plate assembly
1467(P)/GRC144(V) or R-1467(P)A/GRC-144(V) (para
2A16 (fig. 3-21). All of the parts mounted on the rear of
plate assembly 2A16 can be replaced using general
parts replacement techniques (para 3-19).
(2) Disconnect the following coaxial
cables (fig. 324): 2A16W1 from postselector bandpass
3-52. Repair and Replacement of R-1467(P)/ GRC-
filter 2FL5 connector J2. 2A15W3 from electrical
144(V) and R-1467(P)A/GRC-144(V)
frequency synthesizer 2A14 connector output J8 end
a.
General.
Repair of connectors in R-
amplifier-frequency multiplier 2A10 connector J1, and
1467(P)/GRC-144(V)
or
R-1467(P)A/GRC144(V)
2A15W10 from af-rf amplifier 2A11 connector J2.
requires either the replacement of the defective
(3) Disconnect plug 2A16W1P1 (fig. 3-
connector (solder type nonremovable contacts) or the
18) from connector 2A15W2J1.
replacement of defective connector contacts (crimp or
(4) Remove the ten screws (fig. 3-18)
solder type removable contacts). A listing of the R-
securing plate assembly 2A16 to electrical equipment
1467(P)/GRC-144(V) and R-1467 (P)A/GRC-144(V)
cabinet 2A15.
connectors is included in the chart below. The chart
also includes a listing of applicable tools (fig. 3-26), a
(5) Carefully withdraw plate assembly
paragraph reference specifying the applicable repair
2A16 from electrical equipment cabinet 2A15.
procedure, and a figure reference for identification of the
b.
Reassembly.
connector.
(1) Mount plate assembly 2A16 to its
b.
R-1467(P)/GRC-144(V)
and
R-1467(P)
mounting rails in electrical equipment cabinet 2A15.
A/GRC-144(V) Connector Chart.
(2) Replace and tighten the ten screws
removed in step a(3).
Connector
Extraction/
Crimping
Procedure
Figure
insertion tool
tool
paragraph
reference
2A1A5P1 ................................ ......... MS 18278 size 20/none........... MS 3191-4 with Head.......... 3-37c ...............................
2A15W2XA1................................ ..... Same................................ ...... Same ................................ .. 3-37c ...............................
2A16W1XA5................................ ..... Same................................ ...... Same ................................ .. 3-37c ...............................
2A16W1XA8................................ ..... Same................................ ...... Same ................................ .. 3-37c ...............................
2A16W1XA11................................ ... Same................................ ...... Same ................................ .. 3-37c ...............................
2A16W1XA12B................................ . Same................................ ...... Same ................................ .. 3-37c ...............................
2A16W1XA13................................ ... Same................................ ...... Same ................................ .. 3-37c ...............................
2A6XA4 ................................ ............ Same................................ ...... Same ................................ .. 3-37c ...............................
2A16XA7 ................................ .......... Same................................ ...... Same ................................ .. 3-37c ...............................
2A16XA10 ................................ ........ Same................................ ...... Same ................................ .. 3-37c ...............................
2A15W2XA14................................ ... CET-C6B/None....................... None................................ ... 3-37d ...............................
2A16W1XA12A................................ . CET-C6B/None....................... None................................ ... 3-37d ...............................
2A15W2J1................................ ........ MS 24256 R20/A20................. MS3191-4 with Head........... 3-37e
Assy W1
Change 6
3-72
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |