| TM 11-5820-917-13
Preventive Maintenance Schedule
Procedure
Schedule
1. Perform self-test to check receiver operation and
Daily (at beginning of
condition of standby battery. For receiver opera-
each shift).
tion, the main power and standby battery must be
on and the receiver must be sweeping. See para-
graph 5-15 for standby battery test.
2. Check receiver synchronization by actuating
Daily (at beginning of
DISPLAY CYCLE switch. To adjust the display
each shift).
synchronization, sequence MODE switch to the
three SET positions and, in each position, adjust
NOTE
display using the ADV/RET switch. Also check
for evidence of sounder record display dropout.
Adjust only while
A recurring indistinct or broken path display could
selected path sweep
indicate a faulty antenna connection, defective
is in progress.
power divider, or defective receiver preselector
filter.
3. Check operation of 6025 and 4028 exhaust fan
Weekly (daily if in
efficiency. Fan suction should be sufficient
dusty area).
to hold paper placed over intake filter (rear
panel of 6025 and front panel of 4028). If
necessary, remove and clean filter by submerg-
ing in warm water. Thoroughly blow dry with
compressed air.
4. Check frequency standard, and adjust if
Monthly (or if excessive
necessary per paragraph 5-21.
drift is observed on all
paths simultaneously.
5. Make visual inspection of all interconnecting
Monthly
cables and connectors at rear of units. Ensure
that plugs are fully inserted and that no undue
strain is being placed on cables.
6. Remove top covers from receiver units and
Quarterly
make visual inspection of interiors. Ensure that
modules are properly seated and that no loose wires
or signs of overheating exist.
7. Check all low voltage DC power supplies per
Semi-Annually
instructions of paragraph 5-13.
|