| TM 11-5820-917-13
Test Equipment Required
Recommended manufacturer and type
Item
Tektronix 455 (or 465)
Hewlett Packard 5300B
Frequency Counter
Simpson 460 (or Beckman 3020)
Microlab FXR TA-5MN
Termination, 2 watts
Tektronix 011-0059-02
Attenuator, 20 dB
Hewlett Packard 141T
Spectrum Analyzer
Hewlett Packard 8552B
with IF Section
Hewlett Packard 8553B
RF Section
TCS-4B/1024 Unit (BR Communi-
Sweep Generator
cations)
Hewlett Packard 651A
Audio Oscillator
Watkins Johnson MIC
Mixer
Kay Model 432D
Attenuator (Variable)
Lambda LL-903-OV, or LP-552-FM
Power Supply
or HP 6200B
(35 VDC Lab Type)
by replacing the faulty assembly with a known good assembly. The performance
test of paragraph 5-29, figures 5-2, 5-3, 5-4, 5-6, 5-7 and 5-8, and schematics
of Section 7 provide the measurement data that can be used for fault isolation.
voltage protection device, U9 (figure FO-34/1. The overvoltage device accomplish-
es circuit protection by effectively short circuiting the output terminals of the power
transformer when the trip voltage limit is exceeded. The overvoltage device is
connected across the 11 volt terminals and trips at 17 volts. When the trip voltage
is exceeded, the input power fuse is normally blown. This condition should be
noted when troubleshooting and line voltage checked before trying to turn on the
receiver.
ADJUSTMENT
PROCEDURES
before shipment. The following procedures are provided for use following a repair
or as required during the performance verification test.
|