Page Title: Procedure.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-695-35
(4)  Remove components 1A3 and 1A5
(6)  Disconnect coaxial cable 1A15W4
(TM 11-5820-695-12).
from jack 1A12J3 (fig. 3-13), and disconnect plug
1A15P6 from jack 1A15J20 (fig. 3-7).
NOTE
b.
Procedure.
For Radio Sets AN/GRC-144(V)3 and
(1)  Refer to the chart (c below). Connect
AN/GRC-144 (V)4 also disconnect
the multimeter leads between the two pins listed in the
equipment  interconnection  cables
steps of the sections that were referenced in the
from 1A15J22 and 1A15J23 (fig. 3-
troubleshooting chart (para 3-6b). If the troubleshooting
7.1).
chart indicates a section but does not give a step
number, perform all of the steps given in that section
(5)  Disconnect
the
equipment
starting with step a.
interconnections  cables  from  jacks
1A15W27J4,
1A15W27J5, and 1A15W27J6 (fig. 3-7).
(2)  Observe that multimeter indication is
within the tolerance specified In the chart for each step.
NOTE
If it is not, refer to the T-1054(P)/GRC-144(v) or T-
1054(P)A/GRC-144(V) interconnecting diagram (fig. 5-
For Radio Sets AN/GRC-144(V)3 and
15 or 5-15.1) to determine whether the fault is defective
AN/GRC-144 (V)4 also disconnect
wiring or a defective circuit element.
cable
1A15W28
and
1A15W29
connectors 1A15P4 and 1A15P5 from
digital data combiner 1A12 jacks
1A12J1 and 1A12J2 (fig. 3-13).
Change 6 3-16.1/(3-16.2 blank)