TM 11-5820-695-35
Item No.
Symptom
Probable trouble
Corrective action
f. Transmitter frequency mixer stage
f. Turn meter selector switch to ZND
1A9 defective.
MULT. If meter indication is
not in yellow band, proceed to
step q below. If meter indication
is in yellow band, check 1A9 by
substitution.
g. Transmitter frequency multiplier
g. Turn meter selector switch to
group lA10 defective.
AMPL-MULT. If meter indica-
tion is not in yellow band, pro-
ceed to step h below. If meter
indication is in yellow band,
check transmitter frequency
multiplier group 1A10 by
substitution (TM 11-5820-
696-12).
h. Defective wiring in plate assembly
h. Turn meter selector switch to
1A16.
SYNTHESIZER. If meter
indication is not in yellow band,
proceed to step k below. If
meter indication is in yellow
band, perform the plate assembly
1A16 checks (para -10c,
section 7).
t. Coaxial cable 1A15W16 defective-----------i. Check coaxial cable 1A15W16
(fig. 3-13) by substitution.
j. Coaxial circulator 1HY,1 defective-----------j. Check coaxial circulator 1HY1 by
substitution (para -28).
k. Defective wiring in electrical
k. Perform the electrical equipment
equipment cabinet lA15.
cabinet 1A15 checks (para
3-31, section 8).
l. Electrical equipment chassis
l. Replace electrical equipment
1A14A10 defective.
chassis 1A14A10 (para 3-31).
20 SYNTH LOCK indicator
a. Electrical equipment chassis
a. Check electrical equipment chassis
lighted red.
1A14A10 defective.
1A14A10 by substitution (para
3-S1).
b. Defective wiring -------------------------------- b. Remove electrical frequency syn-
thesizer 1A14 (para 38-1) and
alarm monitor 1A5, and check
for continuity between pin 7 of
connector 1A16W27XA14 and
pin 17 of connector 1A16W25-
XASB (fig. 5-15). Also check
resistance between pin 8 and 9
of connector 1A16W26XA5A.
Resistance should be greater than
10 ohms.
21 REFL RF POWER indicator
a. Coaxial cable 1W25 defective---------------a. Check coaxial cable 1W26 (fig.
lighted red.
3-13) by substitution.
b. Directional coupler 1DC1
b. Check directional coupler 1DC1 by
defective.
substitution (para 3-36).
c. Duplexer CU-1891/GRC defective----------c. Check Duplexer CU-1891/GRC
by substitution.
d. Switch, Waveguide SA-1679/
d. Check Switch, Waveguide SA-
GRC defective
1679/GRC by substitution.
22 CABLE TO RADIO MODEM
a. Defective wiring in electrical
a. Perform the electrical equipment
indicator lighted red.
equipment cabinet lA16.
cabinet 1A16 checks (para
(Applicable to standard
311c, sections 4 and 5).
cable terminal operation
b. Digital data modem chassis
b. Replace digital data modem chassis
only).
LA12A12 defective.
1A12A12 (par 3-29).
Change 6 3-6.1/(3-6.2 blank)