| TM 11-5820-695-35
Item No.
Symptom
Probable trouble
Corrective action
14 Speaker output low---------------------------a. Defective component or wire in
a. Perform the electrical equipment
electrical equipment cabinet
cabinet 1A16 checks (para
1A16.
3-11, section 7 (step i, J, and
k)).
b. Speaker 1A15A8LS1 defective--------------b. Check ea- r 1A15A8LS1 by
substitution (fig. 3-4).
c. Orderwire chassis 1A13A7
c. Replace orderwire chassis 1A13A7
defective.
15
Both the green and red lamps
Defective wiring between indicator
Use the T-1064/GRC-144 inter-
of any status or alarm in-
and its associated lamp driver.
connecting diagram (fig. 5-15)
dicator lighted
and TS-862 B/U to isolate the
defective wiring.
16
RING indicator does not
a. Defective wiring in electrical
a. Perform the electrical equipment
light amber when 1600
equipment 1A16.
cabinet 1A15 checks (para
Hz ring signal is present.
3-11c, section 8 (step u)).
b. Orderwire chassis 1A18A7
b. Replace orderwire chassis 1A18A7
defective
17
CNTRL ALARM indicator
a. Defective wiring in electrical
a. Remove the orderwire assembly
lighted red (all other
equipment cabinet 1A15.
1A13 (para 3-30) and use the
alarm indicators lighted
TS-..52 B/U to check for eon-
green).
tinuity between pins 22, 23, and
25 of connector A165W27XA13B
and CABINET GROUND lug
E1 (fig. 6-15). If continuity is
obtained, perform the electrical
equipment cabinet lA16 checks
p, q, and r).
b. Orderwire chassis 1A18A7
b. Replace orderwire chassis 1A1A7
defective
(para 3-0).
18
TRAF indicator lighted red-----------------a. Defective wiring in plate assembly
a. Perform the plate assembly 1A16
1A16
checks (para -10c sections
2, 3, 5, and 6).
b. Defective wiring in electrical
b. Perform the electrical equipment
equipment cabinet 1A1.
cabinet 1A16 cheeks (para
c. Digital data modem chassis
e. Replace digital data modem chassis
1A12A12 defective.
1A12A12 (para 8-29).
19
RF POWER indicator lighted
a. Coaxial cable 1A16W22 defective----------a. Turn meter selector switch on
red.
meter panel assembly 1A15A8
to 3RD MULT (LOCAL OSC).
If meter indication is not in the
yellow band, proceed to step f
below. If meter indication is in
the yellow band, remove alarm-
monitor 1A5 and perform the
plate assembly 1A16 checks
(para 8-1oa, section 4, (step o)).
stage 1A9 defective.
stage lA9 by substitution
(TM 11-5820-695-12).
c. Radio frequency bandpass filter
c. Check radio frequency bandpass
1FL3 defective
filter 1FL8 (para 3-36) by
substitution.
1FL4 defective.
filter 1FIA by substitution (para
e. Connector adapter 1CP4 or direc-
e. Check connector adapter 1CP4 and
tional coupler lDC1 defective.
directional coupler 1DC1 by
substitution (para 336).