| TM 11-5820-695-35
when the shelter waveguide or antenna system cause a
rf input to 14.4 to 15.0 GHz and amplifies it sufficiently
sufficiently high voltage standing wave ratio (VSWR)
to provide a 250 mw nominal output at the electrical
to exist because of faulty waveguide connections, water,
equipment chassis 3A7 J4 ANT waveguide output.
etc. The reflected 14.4 to 15.0 GHz rf power is rectified
Refer to paragraph 2-86 for a complete description of
by power detector 3A7CR1 to provide the dc signal to
amplifier multiplier 3A5 circuit functioning. The rf output
operate alarm monitor 3A1 reflected power monitor
from amplifier multiplier 3A5 RF OUTPUT waveguide
circuits (para 2-87).
flange is applied to the input waveguide flange of
bandpass filter 3A7A4 that is a tunable frequency
selective filter whose output is connected at a rear
(2) The K-band 14.4 to 15.0 rf signal from the
waveguide flange to diplexer 3A7HY1. The bandpass
antenna is applied to the transmit/receive port 2 of
filter 3A7A4 is used for tuning (attenuating frequencies
diplexer 3A7HY1. Diplexer 3A7HY1 routes the rf input
on either side of tuned frequency) amplifier-multiplier
frequency to bandpass filter 3A3 and frequency
3A5 output signals to the antenna. Diplexer 3A7HY1
converter 3A2. Bandpass filter 3A3 is used to tune the
permits diplexing (simultaneously sending and
input frequency for down-conversion to 4.4 to 5.0 GHz
receiving) the 14.4 to 15.0 GHz band frequency from
by the electronic frequency converter 3A2. The diplexer
Antenna AS-3398/GRC-144(V) using a common
3A7HY1 is rf connected to BP filter 3A3 through
antenna and waveguides. The diplexer 3A7HY1 is rf
waveguide adapter 3A7W4 and to the antenna system
connected to BP filter 3A4 through waveguide adapter
through directional coupler 3A7DC1.
Electronic
3A7W4 and to the antenna system through directional
frequency converter 3A2 consists of tunnel diode
coupler 3A7DC1. Diplexer 3A7HY1 (fig. 2-34) consists
amplifier 3A2A1, mixer 3A2A2, local oscillator 3A2A3,
of two circulators which route transmit and receive
attenuator 3A2AT1 and isolator 3A2AT2 circuits whose
signals into the required paths. In each circulator, the
functional descriptions are provided in paragraph 2-84.
RF energy entering at any port circulates in the direction
The output signal from the isolator 3A2AT-2 is the down-
indicated by the arrow and exits at the next circulator
converted 4.4 to 5.0 GHz output from Converter-
port. Directional coupler 3A7DC1 and power detector
Multiplier CV-3633/GRC-144(V) that is applied to
3A7CR1 serve as the sensing network to detect
Receiver, Radio R-1467(P)A/GRC-144 through the
reflected forward power fault conditions
receiver waveguide switch through Adapter, Waveguide
UG-1883/GRC.
Change 6 2-130
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |