TM 11-5820-695-35
USE (GHZ) indicator is lighted green and the lower part,
2-83.
Status Panel 3A8 Functioning
14.4 to 15.0, is lighted white. For K-band operation the
colors are reversed. The control signals are generated
Status panel assembly 3A8 (fig.  5-106) contains the
by the waveguide switches (para. 2-80)
main power switch protective fuses and alarm indicators
to monitor waveguide switch position and the CV-
2-84.
Power Supply 3A6 Functioning
3633/GRC-144(V) and R-1467(P)A/GRC-144 operation.
A description of primary power distribution through
Power Supply 3A6 (fig. 5-103) rectifies ac power from
status panel 3A8 and electrical equipment chassis 3A7
transformer 3A7T1 to provide the required dc operating
is provided in paragraph 3-82.  The POWER 2 AMP
power for the alarm monitor 3A1, electric frequency
SLO-BLO fuse 3A8F1 protects amplifier-multiplier 3A5
converter 3A2 and amplifier-multiplier 3A5 circuits.
heater 3A5HR1 and POWER 1.5 AMP SLO-BLO fuse
Power supply 3A6 contains +28 Vdc and +100 Vdc
3A8F2 protects transformer 3A7T1 from overload
rectifier and regulator circuits.  There are also two
conditions.  Each fuse is housed in a fuse holder
thermal switches 3A6S1 and 3A6S2 that protect power
3A8FX1 and 3A8FX2 that contain a neon indicator that
supply 3A6 +28 Vdc and +100 Vdc circuits from damage
illuminates if a fuse is open.  Status panel 3A8 AIR
due to excessive temperatures caused by circuit
FLOW indicator is discussed in paragraph 2-82c and 2-
overloading. As described in paragraph 2-81, 120 Vac
87 along with alarm monitor 3AT circuit descriptions. All
power is stepped down by transformer 3A7T1.  The
indicators 3A8DS1 through DS13 have one side
outputs from the secondary windings provide the
connected to ground. The other side receives either a
appropriate voltages for the 28 volt 3A6CR5 and
+28 vdc signal (indicator ON) or an open circuit signal
3A6CR6 rectifiers, 100 volt 3A16CR1 through 3A6CR4
(indicator OFF) from the monitored circuit through
rectifiers, +28 V regulator and +100 V regulator boards
3A8J1.
Normal/fault status indicators AIR FLOW,
3A6A1  (fig. 5-104) and 3A6A2 (fig. 5-105).  The
TEMP, and ALARM SUMMARY are lighted green for
following secondary transformer 3A7T1 windings listed
normal status and red for fault status. OSC TEMP and
below supply ac power to power supply 3A6 rectifier
FREQUENCY BAND IN USE (GHZ) are operating mode
circuits.
status indicators. OSC TEMP (white) cycles ON/OFF as
the oscillator temperature varies. For C-band operation,
the upper part, 4.4 to 5.0, of FREQUENCY BAND IN
Winding
Voltage
Power Supply 3A6 Rectifiers
3-4
92V RMS
CR1 through CR4
5-7
72V RMS
CR5 and CR6
8-9
14.7V RMS
A2CR1 through A2CR4
10-11
14.7V RMS
A1CR1 through A1CR4
Change 6 2-132