| TM
11-5820-401-35-1/NAVELEX
0967-432-3020
for conformance with the depot overhaul
3-10. Performance Check and Troubleshooting
standards.
Microphone Amplifier Module A80
Refer to figure 3-4 for schematic diagram of A80
and to figures 3-6 and 3-7 for location of parts.
3-9. Test Equipment and Test Facilities
The following procedures are performed on the
Required
A80 disconnected from the C-2299/VRC:
a. Test Equipment.
a. Test Setup. The following test setup will be
(1) Multimeter TS-353B/U.
used to check the performance of the A80 module
(2) Power Supply PP-1104/G.
(b below).
(3) Voltmeter, Electronic ME-30(*)/U,
(1) Connect the positive terminal of PP-
(ME-30(*)/U represents all models of the volt-
1104/G to terminal 3 and the negative terminal to
meter.)
terminal 1 (ground) of A80.
(4) Generator, Signal AN/URM-127.
(2) Connect a 150-ohm resistor to the output
of AN/URM-127. Connect the output of AN/
(5) Spectrum Analyzer TS-723B/U.
URM-127 and the input of ME-30(*)/U to ter-
(6) Oscilloscope AN/USM-281A.
minals 2 and 1 of A80.
b. Test Facilities.
(3) Connect a 150-ohm resistor to output
(1) Test cable No. 1 (2 each), fabricated in
terminals 4 and 1 of A80. Connect the AN/USM-
accordance with details in figure 3-5.
281A to the TS-723B/U OSCILLOSCOPE ter-
minals.
(2) Test cable No. 2 (2 each), fabricated in
accordance with details in figure 3-5.
b. Performance Check. Connect the test equip-
ment to A80 as explained in a above.
(3) Resistor, 150 ohms, 2 watts (3 each).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |