  | ![]() TB 9-2320-280-35-7 
Section XXX. PAN AND TILT MODULE (PTM) CONTROL ASSEMBLY, CONTROL CABLE ASSEMBLY, 
AND DCM/PTM INTERCONNECT CABLE INSTALLATION 
30-1. Locate, mark, and drill 1.375-in. hole (1) for control cable seal assembly (2) on tunnel (3). 
30-2. Position control cable seal assembly (2) and mark two hole locations (5). 
30-3. Drill two 0.391-in. holes in marked locations (5). 
30-4. Insert two rivet nuts (4) in tunnel (3). 
2 
1 
4 
5 
6.50 
2.00 
2 
~ 
5 
3 
4 
2. CONTROL CABLE SEAL ASSEMBLY  3220908  QTY. 1 
4. RIVET NUT  3221004-14  QTY. 2 
Figure 5-96. 
 | 
| 
 