down latch, and turn to RECORD position.
Cassette spools
should begin to turn. Set level as follows:
(a) If LEVEL meter needle is deflecting between
red and green portions of scale, level is correct.
(b) If needle is not deflecting between red and
green portions of scale, signal from radio receiver is too weak.
Either increase level from receiver or set AGC/ MAN switch to
MAN and adjust GAIN control for a proper signal.
(c) Check headset for a usable level.
(4) To make voice notes over received signal while
recording, press microphone switch and speak into microphone.
It may be necessary to adjust gain or voice loudness to obtain
proper LEVEL meter deflection.
(5) Stop record operation by pressing down latch of
mode selector switch, turning mode selector switch to OFF, and
releasing it.
(6) When end-of-tape tone sounds in headset, set
mode selector switch to OFF. To use second side of tape in the
cassette, proceed as follows. Unlatch and open cassette loading
door. Press eject button, flip cassette over right to left, and
reinsert cassette into compartment. (Side marked 2 should face