| TM 32-5895-206-10
the FUNCTION switch to CAL. Turn the TUNE control to the
calibration mark nearest the desired operating frequency. Tune
in the calibration signal by turning the TUNE control slightly to
either side of the calibration mark. Use the headset and panel
meter to detect the signal. Turn the CAL ADJ control to realign
the tuning scale cursor with the calibration mark. Turn the
FUNCTION switch to OFF. Turn the ANT switch to the desired
antenna input. Turn the TUNE control to the exact operating
frequency. Disconnect the headset.
Calibration Frequencies
R-1218/UR:
0.6 to 4.8 MHz, 0.1 MHz intervals,
5.0 to 20.5 MHz, 0.5 MHz intervals
R-1518/UR:
2.0 MHz intervals
c. Recorder/Reproducer. Be sure the mode selector
switch is in the OFF position. Release the strap over the
cassette loading door, release the door latches, and open the
cassette loading door.
If a cassette is in the cassette
compartment, push the EJECT button and remove the cassette.
Install a fresh cassette with the full spool to the left of the
cassette compartment. (The side marked 1 should face up.)
Close the loading door and secure the latches. The strap may
2-51
|