remain loose until the set is moved. Set the counter to 000 by
pressing the RESET button.
2-8 EQUIPMENT INTERCONNECTION PROCEDURES. Be
sure that the recorder/reproducer mode selector switch is in the
OFF position. Be sure that the receiver FUNCTION switches are
set to OFF. Connect the equipment for the type of operation
desired using the guides below.
a. HF Radio Receiving Set AN/TRQ-30(V1). Connect the
equipment as shown in figure 2-10. For df operation, only the df
antenna should be set up. The headset may be connected to the
recorder/reproducer through the extender cord.
b. VHF Radio Receiving Set AN/TRQ-30(V2). Connect the
equipment as shown in figure 2-11. For df operation only the
appropriate df antenna should be set up. The headset may be
connected to the recorder/reproducer through the extender cord.
c. HF/VHF Radio Receiving Set AN/TRQ30(V4). Connect
the equipment as shown in figure 2-12. Only one receiver is
used at a time. For df operation, only the appropriate df antenna
should be set up. The headset may be connected to the
recorder/reproducer through the extender cord.