| TM 11-6625-847-12
Figure 3-6 (2). -- Continued.
Section II. OPERATIONAL INSTRUCTIONS
3-8.
General
This section provides turn-on, normal operation, and
Switch or control
Setting
shutdown procedures for the 2A/GRC.
PA/RT switch----------------------
PA.
KEY switch -----------------------
OFF.
3-9.
Charts
XMIT STATUS switch-----------
OPR.
The charts given in paragraphs 3-10 through 3-15
REC-XMIT switch ----------------
REC.
provide the operator with a fast, convenient, and safe
method of equipment turn-on; paragraph 3-10 covers
ALC VOLTAGE INFO-----------
Fully counterclock-
the preliminary switch and control settings for the test
control. -----------------------
wise.
set, and paragraphs 3-11 through 3-16 cover the
ALC VOLTAGE TUNE----------
Fully counterclock-
individual test trays used with the test set.
control. -----------------------
wise.
IF OSCILLATOR select --------
4.
3-10.
Test Set, Preliminary Switch and Control
Switch
Settings
MC FREQ 10MC switch --------
0.
MC FREQ 1MC switch ---------
0.
MC FREQ .1MC switch---------
0.
500 VDC LOAD switch ---------
LOW.
Switch or control
Setting
2400 VDC LOAD switch--------
1.
POWER switch ------------------
OFF.
SERV SEL switch
OFF.
3-21
|