| TM 11-6625-847-12
Figure 3-1 (2).-- Continued.
3-3.
Common Module Tray A1, Controls, Indicators, and Connectors
Control, indicator, or connector
Function
POWER switch -------------------------------------------------
Controls +27-volt dc primary power from test set SERV SEL
switch (positions: SS,B/NSK, FSK, AM and CW) to
circuits and connectors on common module tray Al.
DC/DC CONVERTER CONV/REC TEST REG
Permits input current measurement tests of regu-
switch
lator section of dc-to-dc converter and regulator module,
RT-662/GRC.
DC/DC CONVERTER CONV/REC TEST
Permits input current measurement tests of converter
CONV switch
section of de-to-c converter and regulator module, RT-
662/GRC.
DC/DC CONVERTER TE'ST SELECTOR switch ------
Controls DC/DC CONVERTER test points HI and LO for
voltage measurements of dc-to-dc converter and regulator
module, RT-62/GRC at connector J9.
Pos
Action
1 ----------------
Hi test point connected to +27 v dc.
LOW test point connected to ground.
2 ----------------
HI test point connected to switch S1 front.
3-5
|