Control, indicator, or connector
Function
Pos
Action
LOW test point connected to ground.
3 ----------------
HI test point connected to DC/ DC converter.
LOW test point connected to ground.
4 ----------------
HI test point connected to ground.
LOW test point connected to DC/DC
converter.
5 ----------------
HI test point connected to DC/ 'DC converter.
LOW test point connected to DC/DC
converter.
RF AMPL AGC switch ------------------------------------------
When set to ON, variable -dc voltage from RF AMPL AGC
ADJ control is connected to RF AMPL.
DC/DC CONVERTER LOAD SELECT switch -----------
Controls size of resistive load for +20-volt dc regulator section
of dc-to-dc converter module, RT-462/GRC.
Pos
Action
100------------- 196.3 ohms, 100 ma, load.
500------------- 38,3 ohms, 500 ma, load.
600------------- 32A ohms, 600 ma, load.
RF AMPL AGC ADJ control ----------------------------------
Controls level of -dc voltage to contact terminal 1 of RF AMPL
AGC switch.
RF AMPL 100 KC SELECTOR AND 10 KC --------------
Mechanically positions 100 kc and 10 kc shaft
SELECTOR switches ----------------------------------------
couplers for rf amplifier module, RT-662/GRC.
POWER INDICATOR -----------------------------------------
Indicates POWER switch S1, is set to ON, and +27volt dc
primary power is supplied from test set.
J1 -------------------------------------------------------------------
Multipin connector for electrical interconnection of tray Al and
test set.
NOISE BLANKER NOISE BLANKER 20 VDC -----------
For connecting +20 volts dc to noise blanker,
connector -------------------------------------------------------
RT-662/GRC.
NOISE BLANKER (ground) connector -------------------
Ground connector for noise blanker RT-662/GRC.
DC/DC CONVERTER CONV/REC TEST HI -------------
Test point for measuring input current to converter
test connector --------------------------------------------------
or regulator sections of dc-to-dc converter and regulator
module, RT462/GRC.
DC/DC CONVERTEIR CONV/REC TEST CONV
Test point for measuring input current of converter
LOW test connector
section of dc-to-dc converter and regulator module,
RT62/GRC.
DC/DC CONVERTER CONV/REC TEST REG
Test point for measuring input current of regulator
LOW test connector
section of dc-to-dc converter and regulator module, RT -
462/GRC.
DC/DC CONVERTER LOAD SELECT HI test
Test point for voltage measurements of dc-to-dc
connector
converter and regulator module, RT-62/GRC.
DC/DC CONVERTER LOAD SELECT LOW test
Test point for voltage measurements of dc-to-dc
connector
converter and regulator module, RT462/GRC.
DC/DC CONVERTER connector --------------------------
Multipin connector for electrical interconnection of dc-to-dc
converter and regulator module, RT-62/ GRC to tray Al.
DC/DC CONVERTER LOAD SELECT (ground)---------
Ground test point for voltage measurements of
connector
+20-volt dc output of regulator section of dc-to-dc
converter and regulator module, RT-662/GRC.