| TM 11-6625-847-12
CHAPTER 3
OPERATING INSTRUCTIONS
Section I. OPERATING CONTROLS, INDICATORS, AND CONNECTORS
fuses for the test trays used in conjunction with the test
3-1.
Operator's
Controls,
Indicators,
and
set.
Connectors
Note. This section covers only those items
The controls, indicators, connectors, and fuses on the
used when the equipment is being operated; items
front panel of the test set are listed maintenance of the
equipment are covered in paragraph 3-2. Paragraphs
used during tions given for the appropriate category
of maintenance
3-2.
Test Set Controls, Indicators, and Connectors
Control, indicator, or connector
Function
SERV SEL switch -----------------------------------------------
Controls +27-volt de primary power to test set in first four
positions (OFF, OVEN ON, STBY, and SSB/NSK), and
mode of operation of subassemblies, modules, or units of
AN/GRC-106, when connected to the test set.
Pos
Action
OFF
+27-volt de primary power removed from all
circuits
OVEN ON
a. +27-volt dc primary power to regulator
section of dc-to-dc converter and reg
assembly A3.
b. +27-volt dc primary power for OVEN ON.
c. +27-volt de primary power to REC/XMIT
switch S4 contact terminal 9, for RCVR +27
VDC/XMTR GND.
STBY
a. All OVEN ON functions repeated.
b. +27-volt dc primary power for STBY and all
modes
c. PA/RT switch contact terminal 5, section C,
grounded, in STBY and OPER.
SSB/NSK
a. All STBY and OVEN ON functions repeated.
b. PA/RT switch contact terminal 2 and contact
terminal 5, section C, grounded, for +27 V
DC OPR.
c.
+27-volt dc primary power for DC OPR.
3-1
|