TM 11-5820-918-13
2-10. ENVIRONMENTAL CASE ENCLOSURE.  The TCS-4B is supplied in an environ-
mental case.  This configuration is particularly suitable for shock or vibration prone
environments.  The container comes complete with four carrying handles for conven-
ient local transportation.  In addition, front and rear doors remove easily for access
to equipment.  The external dimensions and weight of the unit are shown in figure
2-2. Front and rear covers of environmental case must be removed to provide ade-
quate ventilation when operating the TCS-4B.
POWER
CONNECTION
2-12.  LINE VOLTAGE.  The TCS-4B transmitter may be operated from either 115
or 230 volt (10%), 47 to 440 Hz power lines.  A toggle switch mounted near the power
supply, (refer to figure 2-4) of each of the three units comprising the transmitter
permits easy conversion from either voltage.  Access to the switch is obtained by
removing each unit from the case and removing the top cover of the unit. In the
5018, the top subchassis plate (see fig. 2-3) must also be removed. The switch will
be visible from the top and switch positions are marked 115 and 230. Figure 2-4 shows
the switch location on the power amplifier unit and is typical for the other units.
WARNING
A three-wire (line, neutral, and safety ground) AC line power connection
is required when operating the equipment.  If a 3-wire safety grounded AC
power receptacle is not available, a separate ground wire must be installed
from the chassis ground to an earth ground. Without an adequate ground,
the equipment chassis and frame will float to a dangerously high potential.
NOTE
Before connecting AC power to unit, be sure the correct fuse is installed
as follows:
Type
230V
Unit
115V
1024
1A
1/2 A
Normal Blow
5018
15 A
Slow Blow
8A
4011
1/2 A
1A
Normal Blow
Make sure toggle switch for each unit is in the correct position.