| TM 11-5820-917-13
Remote Data Output Connector
Function
Pin number
Ground
J7-1
S/A Sync, TTL Low = Scan
J7-2
S/A Spectrum Out (O to 5V analog)
J7-3
J7-4
S/A Clock (3.3 kHz)
J7-5
Sweep Run/Stop (SRS) TTL Hi = sweeping
I
J7-6
Receiver AGC Voltage (O to 5V analog)
Upper Frequency Limit (UFL) , TTL Low = 30 MHz
J7-7
TTL Hi = 16 MHz
I
Path 1, TTL low = Path 1 Sweep in Progress
J7-8
Path 2, TTL low = Path 2 Sweep in Progress
J7-9
Path 3, TTL low = Path 3 Sweep in Progress
J7-10
batteries may or may not be installed in the receiver on arrival, depending on shipping
destination and enroute climate, etc. With new batteries installed, the standby supply
To install batteries, proceed
as follows:
Loosen two captive thumbscrews at front of battery drawer on 6025 front panel.
a.
Pull out battery drawer entirely.
b.
Remove two screws at top rear of container and slide battery cover out from
c.
rear.
d. If existing batteries are being replaced, pry center front contact spring back
and remove center tube. Repeat for other two tubes.
e. Replace all batteries in + to - sequence and re-insert each tube according to
polarity markings on base of container.
supply is installed for shipment in a drawer located in the front panel of the 6025 unit.
Since the battery supply may have discharged during shipment, battery power should
not be relied on for the first 12 hours of operation. An internal charging circuit main-
tains a continuous charge on the battery supply when AC line power to the 6025 is on.
After a 12 hour charge (with the 4028 power turned on), the battery pack provides
|