TM 11-5820-890-30-5
16-10. REPLACEMENT OF CONNECTOR CASE. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
p. Screw (19) and
Iockwasher (18)
Use cross tip screwdriver. Install and
hand tighten screw (19) and Iockwasher
(18) securing E1 terminal lug (17) next
to filter mounting plate (22) or on
remaining hole of FILTER EMI-CCA.
q. J5 connector (16)
Position J5 connector (16) next to
mounting hole in connector case (12).
r. J5 connector (16) wires
Use soldering kit and soldering aid. Solder
wires to correct terminals of connector.
s. Tiedown strap (13)
Replace tiedown strap (13) if
removed.
t.
Neoprene gasket
Coat the neoprene gasket of J5
connector (16) with silicone com-
pound, and place the connector in
mounting hole of connector case (12).
u. Two screws (14) and
Use flat tip screwdriver and adjustable
guide pin (15)
wrench. Install and hand tighten two
screws (14) and guide pin (15) securing
J5 connector (16) to connector case (12).
NOTE
Ensure each wire is placed
through mounting hole in
connector case (12).
Before and after soldering
clean wires and terminals
with cotton swabs and
alcohol.
v. Eight screws (5)
Use cross tip screwdriver. Install and
and Iockwashers (6)
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
16-9
|