| TM 11-5820-890-10-8
Transfer COMSEC Keys/FH Data/Sync Time, ANCD to ANCD
5.5c.
(Special Operator Task 1)
DESCRIPTION
During preparations for net opening and during periodic updating of
COMSEC keys, FH data, and sync time stored in the ANCD, it is
necessary to transfer data from one ANCD to another. If such transfers
are not made by communications specialists or designated NCOs,
operators must be able to perform this special task.
Operators perform the actions required in each subtask, in the order
DETAILED FLOWCHART
shown. Results are shown as ANCD displays (dark bordered boxes: or
as RT displays in the form of "RT display shows..." Where appropriate,
results are expressed as explanations of occurrences.
SUBTASKS
ACTIONS
a. Prepare Source ANCD for
Turn Source ANCD ON
(1)
select:
COMSEC/FH transfer
Soi Radio sUpervisor
Send Receive Database
(2) Enter RADIO
sEtup Comsec Time
send to:
(3) Enter SEND
Radio Ancd Stu PC
Loadset Database* Time
(4) Enter ANCD
Eset
Mwod**
Key
Do you want to include time?
(5) Enter DATABASE
(Y/N)
Connect to ANCD and press
(6) Respond YES
[SEND] (WAIT)***
select:
Turn Target ANCD ON
(1)
Prepare Target ANCD for
b.
Soi Radio sUpervisor
COMSEC/FH transfer
(2) Enter RADIO
Send Receive Database
sEtup Comsec Time
receive:
(3) Enter RECEIVE
Ancd Cfd Stu PC Mx
5-45
|