| TM
11-5820-890-10-8
RESULTS
ACTIONS
SUBTASKS
Loadset Database* Time
(4) Enter ANCD
Mwod**
Eset
Key
Do you want to delete FH and
(5) Enter DATABASE
COMSEC data?****
(Y/N)
Connect to ANCD and press
(6) Respond YES
[RCV] (WAIT)***
Transfer in progress
(1)
Press [SEND] on Source
c. Transfer COMSEC/FH
ANCD
Data/Sync Time
Transfer successful
Transfer in progress
(2)
Within 20 seconds, press
[RCV] on Target ANCD
Transfer successful
*
You must enter "DATABASE" in order to proceed.
**
MWOD (Multiple Word Of Day) is a term used in the loading procedure for the Have
Quick radio found in selected aircraft.
***
Do not press [SEND] on Source ANCD until you are ready to press [RCV] on Target
ANCD; then press [RCV] within about 20 seconds of pressing [SEND].
****
You must enter YES in order to proceed.
NOTE:
You can c/ear your ANCD of COMSEC/FH data/sync lime by performing steps b(l)
through b(5), above.