5.4e. Load COMSEC/FH Data/Sync Time into RT Using ICOM Fill
(Primary Operator Task 2)
This task is required in preparation for a Hot Start net opening and,
DESCRIPTION
without sync time, for COMSEC/FH data updates. This task may also
be performed in preparation for a Cold Start net opening by omitting
sync time. Performance of this task involves the use of an ANCD as a
source of COMSEC keys, FH data (hopset, TSK, and net ID), and sync
time. By use of the ICOM fill procedure, COMSEC, FH data, and sync
time are simultaneously loaded into all six channels of the SINCGARS
radio. Upon completion of the ICOM fill, the radio is fully prepared for
secure, frequency hopping communications.
DETAILED FLOWCHART
LOAD COMSEC/FH DATA/SYNC TIME INTO RT USING ICOM FILL
ACTIONS
RESULTS
SUBTASK
(1)
Set COMSEC to CT
(Press PTT twice to clear
a. Prepare RT to receive an
COMSEC alarm)
ICOM fill
(2)
Set FCTN to LD
N/A
(3)
Set CHAN to MAN
N/A
(4)
Set MODE to FH
Display shows "FILL O"
Display shows "OFF"
(5)
Set DATA to OFF*
5-32