| TM 11-5820-695-35
at front panel located adjacent to RF OUT J2 connector.
status panel 3A8. Bandpass filters 3A3 and 3A4 are
nonrepairable assemblies that are replaced at the direct
Remove two nuts screws and nuts that secure the
coaxial mixer to the chassis and remove the coaxial
support maintenance level (para 3-53.5).
mixer and isolator together.
4-11.2. Alarm-Monitor 3A1
(5) Remove rigid coaxial cable and connector
To gain access to alarm-monitor 3A1 printed wiring
plug from tunnel diode amplifier 3A2A1. Remove two
board assembly (fig. 5108) components remove four
panhead machine screws at front panel located adjacent
panhead screws at rear of frame and slide covers
to top portion of RF IN Waveguide flange and four
toward rear exposing wiring board assembly.
panhead machine screws and flat washers located at
bottom of electronic frequency converter chassis and
4-11.3. Electronic Frequency Converter 3A2
remove tunnel diode amplifier.
Depot repair of electronic frequency converter consists
b. Replacement. Replacement consist of-following
of replacement of defective parts. Exercise care when
the reverse order of removal instructions.
removing or replacing rigid coaxial cables. Detail
procedures are provided in TM 11-5820-695-12 for
4-11.4. Amplifier-Multiplier 3A5
removal and replacement of rigid coaxial cables.
Depot repairs to amplifier-multiplier 3A5 consist of
a. Removal.
To replace components in the
replacement of defective parts. Exercise care when
electronic frequency converter 3A2 proceed as follows:
removing or replacing rigid coaxial cables. Detail
(1) Remove two panhead screws at rear of
procedures are provided in TM 11-5820695-12 for
chassis and slide cover toward rear exposing electronics
removal and replacement of rigid coaxial cables.
frequency converter components.
(2) If required remove rigid coaxial cables
a. Removal.
To replace components in the
from component 'to be replaced.
amplifier-multiplier 3A5 (fig. 5110) proceed as follows:
(3) If required remove connector plug and
(1) Remove two panhead screws at rear of
attaching hardware from component to be replaced.
chassis and slide cover toward rear exposing amplifier-
multiplier components.
NOTE
(2) Remove screws and hardware that secure
The coaxial mixer 3A2A2 must be
current regulator 3A5A8 to post and chassis frame.
removed prior to or along with
(3) If replacement of current regulator 3ASA8
isolator 3A2AT2.
To remove the
is required carefully tag then unsolder leads connected
isolator 3A2AT2 perform step (4). To
to current regulator. If access to a component under
remove tunnel diode amplifier 3A2A1
current regulator is required carefully move current
perform step (5).
regulator aside so that wires are not damaged when
removing component.
(4) Remove rigid coaxial cables from coaxial
mixer 3A2A2 and remove two panhead machine screws