| TM 11-5820-695-35
3-78.
CV-3633/GRC-144(V) Local Oscillator Frequency
NOTE
Accuracy Test and Alarm Calibration
Disregard status panel waveguide
switch FREQUENCY BAND IN USE and
a. Test Equipment and Materials
transmitter WAVEGUIDE SW indicator
alarms.
(1) Frequency Counter, Hewlett Packard 5340A.
(2) Insure that transmit switch waveguide is set
to the 15 GHz TEST (TO LOAD) position. For the
(2) Test Cable, N(M) to N(M), Pomona 1680-T-60.
AN/GRC-144 (V)4 optional configuration, insure that
Switch, Waveguide SA-1679/GRC is set to the TO LOAD
(3) Signal Generator, Hewlett Packard 626A.
(TEST) position.
(4) Adapter WG/N(F), Narda 609.
(5) Directional Coupler, Hewlett Packard P752D.
(6) Waveguide, Flexible, HP11503A.
b. Test Connections and Conditions
.
Record the CV-3633/GRC-144(V) operating frequency.
(3) Break waveguide connection at Converter-
NOTE
Multiplier CV-3633/GRC-144 (V) ANT J4 output and first
shelter waveguide connection by removing screws that
To perform the AN/GRC-144(V)4 local
secure waveguide and the CV-3633/GRC-144(V)
oscillator frequency accuracy test and
together.
alarm calibration test, the waveguide
connection at Converter-Multiplier CV-
(4) Move the waveguide to a safe location.
3633/GRC-144(V)
3A7J4
ANT
waveguide flange must be opened.
(5) Interconnect the test equipment in
accordance with the test setup shown in figure 3-39.
(1) Record the T-1054(P)A/GRC144(V) and
CV-3633/GRC-144(V) filter 3A3 and 3A4 operating
c. Initial Test Equipment Calibration.
frequency and dial settings respectively.
allow a 15 minute warmup period.
Change 6 3-108.1/(3-108.2 blank)
|