| TM 11-5820-695-35
Step
Control Setting
No Test Equipment
Equipment Under Test
Test Procedure
Performance Standard
1
FREQUENCY COUNTER
Transmitter T-1054
a. Disconnect coaxial
a. None.
HP 5340A
(P)A/GRC-144(V)
cable from 3A2AT
RANGE: 250 MHz-
POWER ON/OFF
2J2 connector on
18 MHz
switch to OFF.
electronics frequency
RESOLUTION:
converter
10kHz
3A2.
SIGNAL GENERATOR
Converter-Multi
b. Connect the equip-
b. None.
HP 626A
plier CV-3633/
ment as shown in
MOD SELECTOR: CW GRC-144(V) BAND
FREQUENCY DIAL:
SET switch to
(solid line con-
14700 MHz
position 1.
nections).
OUTPUT ATTEN DBM: BP Filter 3A3
ODBM
set to 14700
c. Observe the digital
c. Record for
POWER SET: As
MHz.
display on
reference in
required for-10
the frequency
later steps.
DBM output.
counter.
NOTE
Do not adjust signal
generator fre-
quency or output
level during per-
formance of this
test.
2
Same as step 1.
Receiver, Radio
Connect the equip- The digital dis-
R-1467(P)A/GRC-
ment as shown in
play on the
144(V), FL4 and
figure 3-39 (dash-
frequency
FL5 set to 4700
ed line connec-
counter shall
MHz.
tions).
be the value
recorded in
step 1 minus
10 GHz 100
KHz.
3
Same as 1.
BAND SET switch
Observe digital dis-
The digital dis-
to position 2.
play on the fre-
play on the
quency counter.
frequency
counter shall
be the value
recorded in
step 1 minus
10.02 GHz 100
KHz.
Change 6