Click here to make tpub.com your Home Page

Page Title: Initial Test Equipment Calibration-continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-695-35
Step
Control Setting
No Test Equipment
Equipment Under Test
Test Procedure
Performance Standard
1
FREQUENCY COUNTER
a. Disconnect coaxial
a. None.
HP 5340A
(P)A/GRC-144(V)
cable from 3A2AT
RANGE: 250 MHz-
POWER ON/OFF
2J2 connector on
18 MHz
switch to OFF.
electronics frequency
RESOLUTION:
converter
10kHz
3A2.
SIGNAL GENERATOR
Converter-Multi
b. Connect the equip-
b. None.
HP 626A
plier CV-3633/
ment as shown in
MOD SELECTOR: CW  GRC-144(V) BAND
FREQUENCY DIAL:
SET switch to
(solid line con-
14700 MHz
position 1.
nections).
OUTPUT ATTEN DBM:  BP Filter 3A3
ODBM
set to 14700
c. Observe the digital
c. Record for
POWER SET: As
MHz.
display on
reference in
required for-10
later steps.
DBM output.
counter.
NOTE
Do not adjust signal
quency or output
level during per-
formance of this
test.
2
Same as step 1.
Receiver, Radio
Connect the equip-  The digital dis-
R-1467(P)A/GRC-
ment as shown in
play on the
144(V), FL4 and
frequency
FL5 set to 4700
ed line connec-
counter shall
MHz.
tions).
be the value
recorded in
step 1 minus
10 GHz 100
KHz.
3
Same as 1.
BAND SET switch
Observe digital dis-
The digital dis-
to position 2.
play on the fre-
play on the
quency counter.
frequency
counter shall
be the value
recorded in
step 1 minus
10.02 GHz 100
KHz.
Change 6
3-109