| TM 11-5820-695-35
d. Procedure
Step
Control Setting
No Test Equipment
Equipment Under Test
Test Procedure
Performance Standard
b. Set Converter-
b. None.
Multiplier CV-
3633/GRC-144(V)
bandpass filter
3A4 to 15.0 GHz.
c. Calibrate power c. The CV-3633/
meter and mea-
GRC-144(V)
sure and record
output power
the CV-3633/GRC- as indicated
144(V) output.
on the power
meter shall be
250 milliwatts
(+24 dBm) min-
imum.
Ex.: Same as
step c above.
3
Same as step 1.
N/A
Detune Transmitter- The status panel
Radio T-1054
ALARMS SUMMARY
(P)A/GRC-144(V)
and Transmitter
bandpass filter
T-1054 (P)A/GRC-
1FL3 until power
144(V) CNTRL
meter indicates 6
ALARM indicators
dB less than in-
shall illuminate
dictation recorded
and audible
in step 2c.
alarm sound.
If the alarm in-
dications do not
occur proceed to
step 4 and per-
form the forward
power threshold
alarm calibration-
procedures
and repeat steps
1 b and 2c and 3a.
Change 6
3-104
|