d. Procedure
Step
Control Setting
No Test Equipment
Equipment Under Test
Test Procedure
Performance Standard
NOTE
1 POWER METER HP432A
TRANSMITTER T-1054
MOUNT RESISTANCE:
(P)A/GRC-144
For the AN/GRC-144
100 ohms
BANDPASS FILTER
(V)4 optional configuration
RANGE: 10 mW (10
1FL3 SET TO 4800
figuration set Switch
dBm) CALIBRATION
MHz modulator 1A8
Waveguide SA-1679/GRC
FACTOR:
BAND SET switches
to the TO ANTENNA
As required to
S101: 15 GHz
(NORMAL) position.
match Thermistor-
S102: 14.4 to
a. Set transmit
a. None
mount calibration
14.6997 GHz -
switch wave-
curve.
frequency synthesizer
guide to the
1A14 thumb-
15 GHz OPERATE
wheel switches
position.
4800.0 MHz
b. Adjust AMPL-RF
b. None
CONVERTER-MULTI-
knob 1A3MP9 for
PLIER CV-3633/GRC
a meter indication
-144(V)
of 90 with
BANDPASS FILTERS
meter panel assembly
3A3: 14.8 GHz
METER
3A4: 14.4 GHz
SELECTOR SWITCH
(fig. 3-1) set
to the TRAFFIC
position.
c. Calibrate power
c. The CV-3633/
meter and mea-
GRC-144(V)
sure and record
output power
the CV-3633/GRC
as indicated
-144(V) output.
on the power
meter shall be
250 milliwatts
(+24 dBm) minimum
Ex: Power
meter indication
plus attenture
calibration value
for frequency
equals power
out.
2 Same as step 1.
N/A
NOTE
Repeat paragraph 3-76
steps (1) and b(2).
a. Set controls on
a. None.
transmitter T-
1054(P)A/GRC-144
(V) frequency syn-
thesizer 1A14 to
5000.0 MHz and modulator
1A8 BAND
SET switch to 14.7-
15 GHz, and Filter
1FL3 to 5000 MHz.
Change 6