TM 11-5820-695-35
(10) Secure
top
cover
to
electrical
(5)  Replace BP filters 3A4 and 3A5, with
equipment chassis 3A7.
gasket "O" rings into their respective slots and align
input or output waveguide flanges with waveguide twist
(11) Replace the CV-3633/GRC-144(V) on
W2 and W6.
the R-1467(P)A/GRC-144(V) cabinet.
(6)  Handtighten BP filters and waveguide
(12) Set the T-1054(P)A/GRC-144(V) and
twists together with four screws, flat washers, and
R-1467(P)A/GRC-144(V) POWER ON/OFF switches to
ON.
(7)  Tighten but do not overtighten BP
(13) Set the POWER ON/OFF switch or
filters and waveguide twists together.
the status panel 3A8 to ON.
(8)
Replace BP filters 3A3 and 3A4.
(14) Perform
the
CV-3633/GRC-144
receive section conversion loss test (para 3-79) and
(9)  Replace alarm monitor 3A1 converter
AN/GRC-144(V)4 output power test (para 3-76).
frequency electronics 3A2, amplifier-multiplier 3A5, and
power supply 3A6.