| TM 11-5820-695-35
Figure 3-20. Receiver, Radio R-1467/GRC-144, top view, parts location.
(d) Remove the two nuts, washers, and
(2) Replacement.
Perform steps (2) (a)
the shorting bar from the new meter terminals.
through (k) of paragraph 3-21b to replace indicator light
assembly 2A15A2XDS2 or 2A15A2XDS6.
(e) Connect the wire lugs removed in
step (1) (d) to their respective meter terminals and
c. Replacement
of Potentiometer 2A15A2R3
fasten lugs to terminals with the nuts and washers
To remove a
removed in step (d).
potentiometer, remove equipment power (para 338a),
replace the defective potentiometer, restore equipment
(f) Place the shorting bar removed
power (para 3-8b), and then perform the applicable
from the new meter on the terminal lugs of the old meter
calibration procedure listed in the chart below.
and fasten in place with its terminal hardware.
POTENTIOMETER CALIBRATION
(g) Release the meter panel assembly
Potentiometer
Calibration procedure
2A15A2 and position it downward until it rests against
electrical equipment cabinet 2A15.
2A15A2RS, 2A15A2R4, Calibration of R-
(h) Secure meter panel assembly
1467/GRC
2A15A2 in place by finger tightening the two meter
2A15A2R5, and
144 local oscillator
panel captive screws.
2A15A2R6.
metering circuits.
(i) Calibrate receiver meter 2A15A2M1
2A15A2R7 ....................... Calibration of R-1467/
b. Replacement of Indicator Light Assembly
GRC-144 traffic
metering circuit
(1) Removal. Perform
steps
(1) (a)
through (j) of paragraph 3-21b to remove indicator light
assembly 2A15A2XDS2 or 2A15A2XDS6.
3-62
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |