TM 11-5820-695-35
are lighted green.  If an output data traffic failure is
circuits consist of a meter selector switch and a meter.
A signal is monitored by setting the meter selector
detected by the cable-to-radio circuits in 1A12, the
CNTRL ALARM and the external traffic in indicators
switch to the appropriate position.  Meter calibration
light red.  The CABLE TO RADIO MODEM indicator
resistors are provided for certain meter indications. The
lights red only when a functional failure exists in 1A12
metering circuit also provides a test position which
and actual data traffic is present. If data traffic is not
allows component test lead monitoring.
present, this alarm is inhibited (remains green) even if a
functional failure exists. The orderwire input is either
d.
Power Supply Circuits. Power supply 1A1
two digital orderwire signals (DOW and DVOW) or one
produces regulated +28 vdc, +15 vdc, +12 vdc, -12 vdc,
analog orderwire signal (AVOW). When operating in the
-6 vdc and +5 vdc voltages required to operate the
analog orderwire mode, the AVOW is routed to
circuits  and  indicators  in  Transmitter,  Radio  T-
orderwire assembly 1A13 where it is processed as
1054(P)/GRC-144(V).
described in (2) below. When operating in the digital
orderwire mode, digital orderwire signals are processed
2-3.1.
Overall  Block  Diagram  Description  of
only in digital data combiner 1A12; orderwire assembly
Transmitter, Radio T-1054(P)A/GRC-144(V)
1A13 processes analog orderwire signals but not digital
orderwire. The data signal is scrambled, retimed and
regenerated, and the digital orderwire (DOW and
Transmitter, Radio T-1054(P)A/GRC-144(V) operates in
DVOW) signals are retimed and multiplexed into a
the 4.4 to 5.0 GHz frequency range with a continuous
single bitstream (CVDOW) in digital data combiner
wave (cw) power output of 250 milliwatts nominal.
1A12. The data and CVDOW (multiplexed DOW and
Figure 5-6 illustrates the major signal flow (heavy lines
DVOW) signals are then combined in a linear summing
on the diagram) and the control and alarm signals
amplifier and applied to the radio modulator circuits
between assemblies in the T-1054(P)A/GRC-144(V).
through attenuator 1A3 and af-rf amplifier 1A4. When
The processing of signals within complex assemblies
operating in the analog orderwire mode, this signal is the
such as digital data combiner 1A12, orderwire assembly
data signal only; the analog orderwire signal (AVOW)
1A13, and electrical frequency synthesizer 1A14 are
comes from orderwire assembly 1A13.
explained in subsequent paragraphs.
(2)  The thru ow rec signal is amplified
a.
Transmit Path.  The transmit (cable-to-
in orderwire assembly 1A13 and distributed to Handset
radio) signal path through the T-1054(P)A/GRC-144(V)
H-156/U,  Telephone  Set  TA-312/PT,  attenuator
is shown with the FROM CABLE signal entering the T-
assembly 1A3 (to radio ow), and to the loudspeaker on
1054(P)A/GRC-144(V) on the left and the RF OUTPUT
1A15A8.  The loudspeaker level is controlled by the
signal leaving on the right-hand side of figure 5-6.
SPEAKER VOLUME control. The RING pushbutton on
1A15A8 provides in-band tone signaling to locally
(1)  The FROM CABLE input (data
initiate ow communications.  The RING indicator on
signal from the DGM and orderwire signal from the OCU
1A15A8 lights amber when the RING pushbutton is
and CLED) is applied to the cable-to-radio circuits of
depressed or when a ring signal is received from a
digital data combiner 1A12.  The CABLE TO RADIO
remote ow station.  The CNTRL alarm indicator on
MODEM indicator on meter panel assembly 1A15A8
meter panel assembly 1A15A8 is controlled by alarm
and a remote traffic in indicator are controlled by the
circuits in 1A13. Normally, the CNTRL ALARM indicator
cable-to-radio circuits in 1A12 through the radio patch
is lighted green. If an
panel.  For normal input data traffic conditions, the
CABLE TO RADIO MODEM and the traffic in indicators
Change 6 2-6.1