TM 11-5820-695-35
signal to radio repeater for the radio repeater mode of
(3rd mult) within 1A9 and applied to the metering
operation.
circuits.
(2) The RADIO TO CABLE MODEM
indicator on meter panel assembly 1A15A8 and an
(6)  The 4.55 to 4.85 Hz signal is mixed
external traffic out indicator are controlled by the radio-
with  the  150  MHz  frequency  modulated  signal
to-cable circuits of 1A12 through the radio patch panel.
(containing the pcm signal and orderwire) in transmitter
For normal output pcm traffic conditions, the RADIO TO
frequency mixer stage 1A9 to produce the 4.4 to 5.0
CABLE MODEM and the external traffic out indicators
GHz carrier output signal which is applied to rf bandpass
are lighted green.  If an output pcm traffic failure is
filter 1FL3. The bandpass filter is set to the required
detected by the radio-to-cable circuits in 1A12, the
carrier frequency. The lower side band frequency (local
CNTRL ALARM and external traffic out indicators light
oscillator minus 150 MHz) is selected for the low band of
red. The RADIO TO CABLE MODEM indicator lights
carrier output frequencies (4400 to 4699.9 MHz). The
red only when a functional failure exists in 1A12 and
upper sideband frequency (local oscillator plus 150
actual pcm traffic is present.  If pcm traffic is not
MHz) is selected for the high band of output frequencies
present, this alarm is inhibited (remains green) even if a
(4.7 to 5.0 GHz).  The selected carrier frequency is
functional failure exists.
passed through rf low pass filter 1FL4 to directional
coupler 1DC1.  The main output of the directional
(3)  A  normally  energized  relay  in
coupler is applied to Switch, Waveguide SA1-679/GRC.
orderwire assembly 1A13 is controlled by the recovered
A secondary output is sent to the radio test set. The
ow sense signal from the radio-to-cable circuits in 1A12.
RADIO TEST SET indicator on 1A15A8 lights red when
If the pcm portion of the input signal from Radio,
the radio test set is turned on and green when it is
Receiver  R-1467/GRC-144  is  missing,  the  relay
turned off. In addition, detected forward and reflected rf
becomes deenergized. With the relay deenergized, the
power signals are sent from 1DC1 to alarm monitor 1A5
orderwire signal received from the R-1467/R-144 is
and to the metering circuits in 1A15A8.  For normal
applied to the orderwire circuits in place of the
conditions, the RF POWER and REFL RF POWER
recovered ow signal from 1A12.
Thus, orderwire
indicators are lighted green. A loss of rf power output or
communication is maintained when the pcm traffic
a high level of reflected power will cause the associated
portion of the signal from the R-1467/GRC-144 is lost.
indicator and the CNTRL ALARM indicator to light red.
(4)  A receiver alarm signal is also
b.
Receive Path.  In the receive (radio-to-
applied to the alarm circuit in 1A13 from the R-
cable) signal path through the T-1054/GRC-144, the
1467/GRC-144. If an alarm condition is present in the
combined pcm and ow signal from Receiver, Radio R-
.R-14W7/GRC-144, this signal will cause the CNTRL
1467/GRC-144 is applied to the radio to-cable circuits of
ALARM indicator on 1A15A8 to light red and the
1A12 through orderwire assembly 1A13 and the radio
loudspeaker to sound an audible alarm.
patch panel. Note also in figure 5-6 that the radio patch
panel is used to connect the radio-to-cable circuits of
(5)  The pcm aim signal from digital
1A12 in the signal path for the radio repeater mode of
data modem 1A12 summaries the alarm conditions
operation.
within 1A12. It is applied to the alarm circuits in 1A13
along with the transmitter and receiver alarm signals to
(1)  The radio-to-cable circuits separate
control the CNTRL ALARM indicator and audible alarm.
the pcm reshaped and retimed for application to the
Since the cable-to radio circuits in 1A12 are not used in
cable system. The recovered ow signal is amplified and
the radio repeater configuration, a cable-to-radio alm
fed back to 1A13 through the radio patch panel along
inhibit signal is applied to the radio patch panel. When
with the recovered ow sense signal. The recovered ow
the radio patch panel is connected in the RADIO
signal is amplified in 1A13 and distributed to Handset H-
REPEATER MODE OF OPERATION, this signal inhibits
156/U, Telephone Set TA-12/PT, the loudspeaker, and
the cable-to-radio alarm circuits in 1A12 from activating
back (thru ow send) to the radio-to-cable circuits in
the CNTRL ALARM indicator and the audible alarm.
1A12. The pcm and ow signals are then combined with
the direct current (from the cable-to-radio circuits) and
c.
Metering Circuits.  Signals from various
the composite signal is applied to the cable system.
components in the T4064/GRC-144 are monitored at
The radio-to-cable circuits also provide a pcm output
meter panel assembly 1A15A8. The metering
2-6