| TM 11-5820-695-35
level signal is also routed to the metering circuits in
assembly 1A13. The direct current portion of the input
1A15A8 through alarm monitor 1A5.
signal is looped back to the TO CABLE output of T-
1064/GRC-144 by way of the cable-to-radio and the
(4) The combined pcm and ow signal
radio-to-cable circuits of 1A12 (para 22a(1)).
frequency modulates a 150 MHz carrier in 1A8.
Electronic frequency control 1A7 provides automatic
(2) The thru ow rec signal is amplified
frequency control (afc) of the 150 MHz carrier.
in orderwire assembly 1A13 and distributed to Handset
Frequency control and modulator signal levels from 1A7
H-156/U, Telephone Set TA-12/PT, attenuator assembly
and 1A8 are applied to the metering circuits in 1A15AB.
1A3 (to radio ow), and to the loudspeaker on 1A15A8.
The 150 MHz frequency modulated output of 1A8 is
The loudspeaker level is controlled by the SPEAKER
applied to transmitter frequency mixer stage 1A9 where
VOLUME control. The RING pushbutton on 1A15A8
it is mixed with a 4.55 to 4.856 GHz local oscillator
provides in-band tone signaling to locally initiate ow
signal which is produced by electrical frequency
communications. The RING indicator on 1A15A8 lights
synthesizer 1A14 and a times 16 multiplier chain. The
amber when the RING pushbutton is depressed or when
electrical frequency synthesizer generates a highly
a ring signal is received from a remote ow station. The
stable frequency in the range of 284.375 to 308.125
CNTRL ALARM indicator on meter panel assembly
MHz. The detected output level (synth level) is applied
1A15A8 is controlled by alarm circuits in 1A13.
to metering circuits on 1A15A8. The SYNTH OVEN
Normally, the CNTRL ALARM indicator is lighted green.
lamp (press-to test) on meter panel assembly 1A15A8
If an alarm condition (pcm aim, transmitter aim, receiver
lights white when the standard radio frequency oscillator
aim, or remote traffic in aim) is detected, the CNTRL
oven in 1A14 is at the correct temperature. In addition,
ALARM indicator lights red and an audible alarm is
a synthesizer monitor signal is applied from 1A14 to
heard over the loudspeaker. The RESET pushbutton on
alarm monitor 1A5. This signal indicates if the radio
1A15A8 or the external alarm disable switch is used to
frequency oscillator and the standard radio frequency
silence the audible alarm; however, the red CNTRL
oscillator contained in 1A14 are phase locked. If an in-
ALARM indication will remain until the alarm condition is
phase lock condition exists, the SYNTH LOCK indicator
removed. The WAVEGUIDE SW indicator on 1A15A8
on 1A15A8 lights green. An out-of-phase lock condition
is lighted green when Switch, Waveguide SA-1679/GRC
causes the SYNTH LOCK and CNTRL ALARM
is set to the ANTENNA (NORMAL) position and lights
indicators to light red. The 284.375 to 303.125 MHz
red when the SA-1679/GRC is set to the TO LOAD
output from 1A14 is applied to the times 16 multiplier
(TEST) position.
chain which is comprised of transmitter amplifier-
frequency multiplier 1A11, coaxial circulator 1HY1, and
(3) Attenuator assembly 1A3 provides
transmitter frequency multiplier group 1A10. The signal
attenuation and phase shift circuits for the to radio pcm
is amplified and multiplied to 1137-1213 MHz in 1A11.
and attenuation to ow signals. A detected ow test signal
The signal is then coupled through 1HY1 to 1A10.
from 1A3 is applied to the metering circuits on 1A15A8.
Coaxial circulator 1HY1 provides isolation between the
The pcm and ow output signals from 1A3 are combined
frequency multiplier circuits. Transmitter frequency
at the output of af-rf amplifier 1A4. The pcm signal is
multiplier group 1A10 multiplies the 1137 to 1213 MHz
amplified in 1A4 and the combined pcm and ow output
signal up to the 4.55 to 4.85 GHz local oscillator
is applied to 45 MHz low pass filter 1A6. The 4.6 MHz
frequency for application to transmitter frequency mixer
low pass filter shapes the pcm signal before it is applied
stage 1A9. Detected signal levels in the times 16
to radio transmitter modulator 1A8. A detected traffic
multiplier chain are applied to the metering circuits in
level signal (representative of the input to 1A8) is fed
1A15A8. The 1137 to 1213 MHz output of 1A11 is
back to the alarm monitor 1A5 through attenuator
detected (ampl-mult) within 1HY1 and applied to the
assembly 1A8. If the traffic level signal is present
metering circuits.
The 2275 to 2425 MHz signal
(normal condition), alarm monitor 1A6 causes the TRAF
generated by the 2nd frequency multiplier circuits in
indicator on 1A15A8 to light green. If the traffic level
1A10 is detected (2nd mult) and applied to the metering
signal is absent (alarm condition), 1A5 causes the TRAF
circuits. The 4.55 to 4.85 GHz output generated by the
and CNTRL ALARM indicators to light red. The traffic
3rd frequency multiplier circuits in 1A10 is detected
2-5
|