| TM 11-5820-554-12
Figure 7-5. PP -3 990/FRC -93 assembled to Collins KWM-2/2A.
Section II. POWER SUPPLY PP-4151/FRC-93
equipment. In the Collins KWM-2/2A, this function is
7-7. Description
provided whenever the transceiver OFF-ON-NB-CAL
switch is set to ON, NB, or CAL
Power Supply PP-4151/FRC-93 (Collins 516F-2)
7-8. Tabulated Data
provides all operating voltages for the Collins KWM-
Input requirements
115 or 230 volts, 50 to 400 Hz,
2/2A. It operates from a 115- or 230-volt, 50- 400-Hz
2 or 4 amperes. (Remove capacitor C1
power source to provide high voltage d.c., low voltage
when using a line frequency higher than
60Hz.)
d.c., variable d.c. bias, and an a.c. filament supply that
Output (nominal):
is connected to associated equipment by a 60-inch
Heater power
6.3 volts at 10.0 amperes.
Low voltage B
300 volts d.c. at 170 ma
length of cable and terminated in an 11-pin female
285 volts d.c. at 210 ma.
cable connector. This 11-pin female cable connector
mates with a male power receptacle located on the
High voltage B+
940 volts d.c. at 55 ma.
820 volts d.c. at 230 ma
Collins KWM-2/ 2A. As supplied, the PP -4 151/FRC-
Bias voltage
-55 to -88 volts, no current
93 is wired for 115-volt operation. It is equipped with a
requirement
Ambient temperature range
0 to +50 .
C
ventilated cabinet having four rubber feet for table
mounting. To apply power to the PP-4151/FRC-93,
two pins on the 11-pin female cable connector (P2-7
and (P2-7 are connected together in the external
7-9. Items Comprising Power Supply PP-41 51 /FRC-93
Dimensions
Weight
NSN
Item
Height
Depth
Width
(lb)
5820-00-034-4239
Power Supply PP-4151/FRC-93 (Collins
7
9 7/8
11
30
516F-2)