TM 11-5820-554-12
mating-type connector, use the adapter furnished, and
93 is set to the proper position before
ground the green wire. It is desirable to make a ground
plugging in the a.c. source. It is fused for
connection  to  the  PP-3990/FRC-93KWM-2/2A
4-ampere primary current on 110-volt a.c.
combination, and the three-wire a.c. cord offers the
and for 2-ampere primary current on 220-
most convenient arrangement.
volt a.c. If the switch is set to the 110-
g. Set the Collins KWM-2/2A MIC GAIN control
volt position and the power supply is
fully counterclockwise until the switch clicks. Set the
operated from a 220-volt a.c. source,
OFF-ON-NB-CAL switch to ON. Set the meter switch
damaging high voltages may be developed
to PLATE and the EMISSION switch to LOCK. The
before the fuse blows.
transceiver is in receive condition during warm-up, so
a. Do not operate the power supply and transceiver
the meter will read full scale until the filaments reach
inside the carrying case with the cover closed. Be sure
operating temperature. This is normal S-meter action.
adequate ventilation is provided for the heat generating
When the S-meter falls back to zero, the circuits will
components of the equipment. The output is adequate
have switched to transmit condition and the meter will
for maximum KWM-2/2A ratings in LOCK key under
indicate plate current at approximately 40 ma. If plate
intermittent conditions. DO NOT operate in LOCK
current is other than 40 ma, adjust BIAS ADJUST
key or TUNE position under continuous key down
potentiometer R8 at the rear (fuse side) of the PP-
conditions.
3990/FRC-93 to set plate current to 40 ma.  This
b. No other operating procedures are required.
setting is the proper idling current value for the Collins
Operation of the power supply is controlled from the
KWM-2/2A power amplifier tubes for linear operation.
switches and relays in the Collins KWM-2/2A.
The PP-3990/FRC-93-KWM-2/2A is now ready for
7-6.
Operator's
and
Organizational
use.
Maintenance
7-5. Operation
Operator's maintenance instructions are covered in
CAUTION
paragraph 7-26 and 7-27. Organizational maintenance
Be certain the 110/220 LINE VOLT
instructions are covered in paragraph
SELECTOR  SWITCH  on  the  PP-
3990/FRC
Figure 7-4. Phone jack assembly during assembly.
7-4