| TM 11-5820-509-35
thoroughly stabilized before each
off position until instructed to apply
primary power.
(3) Measure the output frequency at
(1) Connect the test equipment to the test
connector 500 KHZ A3.
The reading must be
fixture es shown in figure 6-16. (The connections for the
500,000.00 0.05 Hz. Adjust capacitor C1 (on top of
remaining test instruments are detailed in the
the module) until this reading is obtained.
appropriate procedural steps below.)
6-16. Oscillator Control C-4311/PRC-47 (A8A7)
(2) Verify that Radio Frequency Oscillator 0-
1032/PRC-47 is seated securely in its connector within
the test fixture.
a. Test Equipment and Material.
(3) Before installing Oscillator Control C-
(1) Frequency Counter AN/URM-79/U
4311/PRC-47 in the test fixture, remove the top cover.
(2) Multimeter ME-26A/U
NOTE
(3) Oscilloscope AN/USM-50
Verify that the coupling halfs on the
(4) Power Supply 124 volts dc) Harrison
drive end of the C-4311 /PRC-47 are
6202B (or equal)
in the positions shown in figure 3-63
(5) Signal Generator SG-103/URM-25F (2)
and that the controls (S1 and S2) on
required)
the front of the test fixture are in
(6) Test fixture for C-4311/PRC-47 with
positions O and OO respectively
Radio Frequency Oscillator 0-1032/PRC-47 installed.
before installing the module in its
b. Test Conditions and Equipment Connections.
connector.
CAUTION
(4) Carefully install the module in the test
Before connecting the power supply
fixture and place the power ON-OFF switch to ON. Turn
to the test fixture, set the output
on the power supply and adjust the output voltage of the
voltage to 19.0 2.0 volts dc; then
24-volts dc power supply to 20.0 0.2 volts dc.
return the power on-off switch to the
Figure 6-16. Oscillator Control C-4311/PRC-47 (A8A7) , Performance Tests, Initial Test Equipment Connections.
6-31
|