TM 11-5820-509-35
(4) On the front panel of the test fixture,
c. Pulse Generator Output.
leave switch S1 at O and rotate switch S2 one complete
(1) Connect  the  vertical  input  of  the
revolution clockwise to a reading of 1.0.
oscilloscope and the frequency counter to 100 kHz
(5) Adjust capacitor C88 (fig.  3-104) for
sinewave input test point (fig. 3-83) and verify that the
minimum 100-kHz modulation on the oscilloscope trace
amplitude of the waveform is 1.8 0.5 volts peak-to-
and observe that the waveform amplitude is not less
peak, and that the pulse width is 0.3 0.1 microsecond.
than 3.4 volts peak-to-peak and the frequency counter
NOTE
indicates 1.7 MHz.
The pulse width is the interval
(6) Repeat step (4) except rotate switch S2
between the points on the wave-form
one complete revolution clockwise to a reading of 2.0.
where 10 % of the peak amplitude
(7) Adjust capacitor C86 (fig.  3-104) for
occurs.
minimum 100-kHz modulation on the oscilloscope trace
(2) Connect the oscilloscope and frequency
and observe that the waveform amplitude is not less
counter to the 500 kHz input test point (fig. 3-83) and
than 4.3 volts peak-to-peak and the frequency counter
verify that a 500-kHz sinewave signal of approximately
indicates 1.6 MHz.
1.5 volts peak-to-peak is present.
(8) Repeat step (4) except rotate switch S2
(3) Connect  the  vertical  input  of  the
one complete revolution clockwise to a reading of 3.0.
oscilloscope and the frequency counter to the 1 MHz
(9) Adjust capacitor C84 {fig.  3-104) for
pulses test point (fig. 3-83) and verify that the amplitude
minimum 100-kHz modulation on the oscilloscope trace
of the waveform is 6.0 2.5 volts peak-to-peak, and that
and observe that the waveform amplitude is not less
the pulse fall time is 0.1 0.03 microsecond.
than 3.4 volts peak-to-peak and the frequency counter
NOTE
indicates 1.5 MHz.
The pulse fall time is the total
(10) Repeat step (4) except rotate switch S2
interval required for the wave to
one complete revolution clockwise to a reading of 4.0.
return to the base line from its peak
(11) Adjust capacitor C82 (fig.  3-104) for
value.
minimum 100-kHz modulation on the oscilloscope trace
(4) With the oscilloscope connected as in
and observe that the waveform amplitude is not less
step (3), adjust capacitor C15 (fig. 3-102) for minimum
than 2.8 volts peak-to-peak and the frequency counter
500 kHz signal in the 1 MHz pulses. Repeat step (3) if a
indicates 1.4 MHz.
major adjustment is made.
(12) Repeat step (4) except rotate switch S2
d. 1.8- to 0.9-MHz Ringer Circuit Alignment.
one complete revolution clockwise to a reading of 5.0.
NOTE
(13) Adjust capacitor C80 (fig.  3-103) for
Verify  that  the  ringer  circuit  is
minimum 100-kHz modulation on the oscilloscope trace
operating properly and not merely
and observe that the waveform amplitude is not less
oscillating.
If  oscillating,  the
than 2.6 volts peak-to-peak and the frequency counter
frequency will change smoothly as
indicates 1.3 MHz.
the setting of the trimmer capacitor
(14) Repeat step (4) except rotate switch S2
is varied.  If ringing, the wavetrain
one complete revolution clockwise to a reading of 6.0.
will
he
ragged
until
proper
(15) Adjust capacitor C78 (fig.  3-103) for
adjustment  of  the  trimmer  is
minimum 100-kHz modulation on the oscilloscope trace
obtained, and then the wavetrain will
and observe that the waveform amplitude is not less
stabilize.
than 2.8 volts peak-to-peak and the frequency counter
(1) Verify that switches S1 and S2 on the
indicates 1.2 MHz.
front panel of the test fixture are at O and OO
(16) Repeat step (4) except rotate switch S2
respectively.
one complete revolution clockwise to a reading of 7.0.
(2) Adjust the oscilloscope sweep rate to 10
(17) Adjust capacitor C76 (fig.  3-103) for
microseconds per centimeter and connect the vertical
minimum 100-kHz modulation on the oscilloscope trace
input and the frequency counter to the 1.8 - 0.9 MHz
and observe that the waveform amplitude is not less
input test point (fig. 3-83).
than 3.6 volts peak-to-peak and the frequency counter
(3) Adjust capacitor C90 (fig.  3-104) for
indicates 1.1 MHz.
minimum 100-kHz modulation on the oscilloscope trace
(18) Repeat step (4) except rotate switch S2
and observe that the waveform amplitude is not less
one complete revolution clockwise to a reading of 8.0.
than 2.3 volts peak-to-peak and that the frequency
(19) Adjust capacitor C74 (fig.  3-103) for
counter indicates 1.8 MHz.
minimum 100-kHz modulation on the oscilloscope
6-32