| TM 11-5820-509-35
and J12. The cw oscillator output frequency shall be
(8) Power Supply (-110 volts dc), Harrison
800 50 Hz.
6207B, or equal
(4) Operate the KEY switch between the
(9) Resistance Decade Box MX-3991/V
MOM ON and OFF positions and observe the
(10) Signal Generator SG-103/URM-25F
waveshape on the oscilloscope and listen to the output
(11) Spectrum Analyzer AN/UPM-110
tone in the loudspeaker. The tone must be free from
(12) Test fixture for AM-3507/PRC-47 (fig. 6-
chirps and clicks, and the waveform shall display no
5)
sharp transients.
(13) Voltmeter ME 30A/U
(5)
When the KEY switch is held ON, the
b. Test Conditions and Equipment Connections.
VOX ON lamp lights.
CAUTION
6-11. Amplifier-Modulator AM-3507/PRC-47 (A8A2)
Before
connecting
the
power
supplies to the test fixture, set their
a. Test Equipment and Material.
output voltages to 26.0 2.0 volts
(1) Audio Oscillator TS-382/U
and -110 5 volts respectively. Then
(2) Converter (for spectrum analyzer),
return the power on-off switches to
Hewlett-Packard K15-8551B
the off position until instructed to
(3) Distortion Analyzer TS-723/U
apply primary power to them.
(4) Frequency Counter AN /URM -79/U
(1) Connect the test instruments to the test
(5) Multimeter ME-26A/U
fixture as shown in figure 6-12. (The connections for the
remaining test equipment are detailed in the appropriate
(6) Oscilloscope AN/USM-50
procedural steps below.)
(7) Power Supply (24 volts dc), Harrison
6202B, or equal
Figure 6-12. Amplifier-Modulator AM 3507/PRC-47 (A8A2), Performance Tests, Initial Test Equipment
Connections.
6-16
|