| TM 11-5820-509-35
CHAPTER 6
DEPOT OVERHAUL STANDARDS
Section I. GENERAL
conducted using the bench test facilities provided by the
6-1. Scope
special test fixtures described in section I. Section II I
tabulates the overall equipment performance tests
This chapter contains the depot-level performance
indicated elsewhere in this technical manual, lists the
standards tests and defines the acceptable limits of
overall equipment adjustments and alignment routines,
operational performance for a repaired Radio Set
and provides a table of final equipment standards of
AN/PRC-47. Section I contains general information
performance.
applicable to the test procedures and test equipment,
and includes construction details and schematic
6-2. General
diagrams for special test fixtures required for bench test
of modular subassemblies of the AN/PRC-47. Section II
lists the performance tests and specific procedures to be
a. The following table provides a list of test
conducted for the evaluation and adjustment of plug-in
equipment required for performance of these standards
modules of the radio set. These tests are
tests.
Test equipment
FSN
Technical manual
Ac Ammeter, 0.5 amperes (Weston #904, or equal)
Ac Voltmeter, 10 mv to 15,000 mv 12500 volts dc insulation)
Audio Oscillator TS-382/U
6625-246-8729
TM 11-6625-935-12
Cable Assembly Set AN/PRA-4
5995-973-3686
Coaxial Adapter, Tee UG-28A/U
Coaxial Adapter, Tee UG-274B/U
Dc Ammeter 0-1 ampere (Simpson #375. or equal)
Dc Ammeter 0-15 ampere (Simpson #375, or equal)
Distortion Analyzer TS-723/U
Frequency Counter AN/URM-79/U
Multimeter ME-26A/U
6625-542-6407
TM 11-6625-200-15
Oscilloscope AN/USM-50
TM 11-5129
Output Meter TS-585/U
TM 11-5017
Power Supply, 7 vdc 600 ma (Harrison 6203B, or equal)
Power Supply, 26 vdc, 500 ma (Harrison 6202B, or equal)
Power Supply, 26 vdc, 15 Amp. (Harrison 6434B, or equal)
Power Supply, 110 vdc, 5 ma. (Harrison 6207B, or equal)
Radar and Radio Repair Tool Kit TK-115/G
Receiver R-1433/UR
Resistance Decade Box MX-3991/V
Signal Generator SG-103/URM-25F (2 required)
Spectrum Analyzer AN/UPM-110
TM 11-6626-326-12
Up-converter for AN /UPM - l 10 (Hewlett Packard K 15-855 1B)
Voltmeter ME-30A/U
b.The following table lists the special tools and test fixtures required for performance standards tests
Special tool
FSN
Ref drawing
Gage. thickness (feeler) 0.002 to 0,020
5210-031-1504
Gage, plug (depth) (u/w CV-1377A/PRC-47)
Gage, overtravel 0.041.inch
Output attenuator, 50: 1
Test fixture for AM-3506/PRC-47
Test fixture for AM-3507/PRC-47
Test fixture for CV-1377A/PRC-47
Indexing fixture for CV-1377A/PRC-47
Test fixture for PP-3518/PRC-47
Test fixture for 0-1032/PRC-47
Test fixture for C-4311/PRC-47
6-1
|