| TM 11-5820-509-35
CHAPTER 4
GENERAL SUPPORT MAINTENANCE
with each respective performance standard to assure
4-1. General
proper operation of the radio set.
a. The tests presented in this chapter verify the
4-2. Test Equipment Required
proper operation of Radio Set AN/PRC-47 after repair
procedures have been completed.
All test equipment and materials required to perform the
b. The instructions that precede each performance
procedures shown in this chapter are listed in the
chart establish the test conditions and present specific
following chart. No special tools or materials are
information for a given test. Perform each test in the
required for these tests.
sequence shown being careful to complete all actions
required by the procedure. The test results must agree
Test equipment
FSN
Technical manual
Multimeter ME-26A/U
6625-542-6407
TM 11-6625-200-15
Oscilloscope AN/USM-50
TM 11 -5 129
Signal Generator SG-103/URM-25F
Frequency Counter AN/URM-79/U
Audio Oscillator TS-382/U
6625-246-8729
TM 11-6625-935-12
Dummy Load DA-75/U
Cable Assembly Set AN/PRA-4
5995-973-3686
Output Meter TS-585/U
TM 11 -5017
Radar and Radio Repair Tool Kit TK-87/U
Radar and Radio Repair Supplementary Tool Kit TK-88/U
Spectrum Analyzer TS-723A/U
6625-668-9418
TM 11 -5097
4-5. Physical Tests and Inspection
4-3. Test Facilities
Perform each of the following steps to assure
compliance with the maintenance standard.
A primary power source of 115 volts, 400 Hz, single-
phase alternating current at approximately 3.0 amperes,
and a 26.5-volt direct current source at approximately
NOTE
11 amperes is required for these tests.
Remove Radio Receiver-Transmitter
4-4. Modification Work Orders
RT-671/PRC 47 from its case using
the procedures detailed in paragraph
The performance standards listed in the tests (pare 4-5
3-11.
through 4-19) assume that all applicable modification
work orders have been performed.
Test
Radio
Step equipment control
Test
Performance
settings
settings
procedures
standards
1
n/a
n/a
a. Inspect all gears and mechanical assemblies
a. Screws, setscrew, bolts, and nuts must
for loose or missing hardware.
be tight, no missing parts.
b. All items secured tightly to panel with no
fuse holders, and lamp sockets for looseness
evidence of damage.
or damage.
2
n/a
n/a
a. Rotate whole megahertz frequency control
a. Bandswitch gears in signal data translator
knob one step at a time from 2000 to 11000
(A3), oscillator control (A7), and in
on KILOCYCLES indicator.
Bandswitch assembly, rotate freely one
step at a time as knob is turned.
3
n/a
n/a
b. Slug rack in signal data translator (A3)
step at a time from X000 to X900 on
withdraws smoothly as knob advances
KILOCYCLES indicator.
one step at a time.
a. Inspect case and chassis for damage,
a. No damage or missing parts visible;
missing parts, the condition of the finish, and
external surfaces originally painted show
panel lettering. Modules must be removed to
no bare metal. Panel lettering legible.
complete this inspection.
NOTE
Paint should be touched up in lieu of refinishing whenever practical. Screw heads, binding posts, receptacles, and plated
parts are not painted and must not be polished with abrasives.
b. Inspect all wiring in the area of repairs for
b. All repaired or disturbed electrical wiring
cracks, chips, or other breaks in the moisture-
and components are secured and
proofing varnish.
moisture-proofed.
Change 1 4-1
|